Nokia DNT2Mi-fp user manual Mean time between failure Mtbf, Electromagnetic compatibility, Safety

Models: DNT2Mi-fp

1 60
Download 60 pages 12.06 Kb
Page 43
Image 43

Technical specifications

Table 7. DNT2Mi-fp power supply (Continued)

Voltage

90 to 264 VAC

 

 

Frequency

47 to 65 Hz

 

 

DC power supply

 

Voltage

48V (40V to 70V)

Remote power supply

Voltage

50 to 150 V on both pairs as generated through ACL2i

 

at central site

 

 

Start-up voltage

Min. 90 VDC

 

 

Table 8. Mean time between failure (MTBF)

DNT2Mi-fp

> 75 years

Electromagnetic compatibility (EMC) of DNT2Mi-fp complies with the following specifications:

Table 9.

Electromagnetic compatibility

 

 

EN 55022: 1998 Class B

Emission, Information technology equipment

 

 

EN 55024: 1988

Immunity, Terminal equipment

 

 

EN 300286: 2000

EMC, Telecommunications equipment

 

 

 

Table 10. Safety

Safety IEC 60950-1 and IEC 60950-21 RFT-C

Protective earthing and Basic insulation

AC Power supply:

Surge protection: 2.5kV according to ITU-T Rec. K.45

DC Power supply:

Surge protection: 0.5kV according to EN61000–4–5

Line Interface:

Surge protection: 1.5kV according to ITU-T Rec. K.45

50 Hz common mode test according to ITU-T Rec. K.45

600V RMS common mode according to ITU-T Rec. K.45

DN0445814

© Nokia Corporation

43 (60)

Issue 2-0 en

Nokia Proprietary and Confidential

 

Page 43
Image 43
Nokia DNT2Mi-fp user manual Mean time between failure Mtbf, Electromagnetic compatibility, Safety, DC power supply