Norcold 442, 483, 463, 453, 482 Side Wall Clearance - Figure, Upper Side Wall Exhaust Vent For Mod

Models: 442 452 462 443 482 453 463 483

1 23
Download 23 pages 8.67 Kb
Page 7
Image 7
Side Wall Clearance - Figure 4

Side Wall Clearance - Figure 4

1. Figure 4 illustrates the requirement to minimize the clearance at the sides of the refrigerator. The clearance is not to exceed 1/2 inch. Side clearances in excess of 1/2 inch must be either

B

filled with Fiberglas batting or blocked with pan- eling, etc.

1

1

Figure 4

Upper Side Wall Exhaust Vent For Mod-

1

els 452, 453, 442, and 443 ONLY

Figure 5

2

 

 

1.

Area above refrigerator blocked (baffled) off to

 

 

prevent trapping of hot air above the refrigera-

 

 

tor.

 

2.

0 - 1/4 inch clearance at the top of the refrig-

 

 

erator.

 

3.

Upper Side vent Location. Floor level to top of

 

 

opening. 38 1/8" for models 442 & 443. 50 1/2"

6

 

for models 452 & 453. See Table 1 for vent

 

 

 

dimensions,

 

4.

0 - 1 inch clearance at the rear of the refrigera-

 

 

tor. (See Figure 3 when clearance exceeds 1

 

 

inch).

 

5.

Intake (lower) vent installed flush with the sur-

Figure 5

 

face on which the refrigerator is mounted.

 

 

6.

O inch clearance at bottom of refrigerator.

 

4

3

5

 

 

 

1

Top and Side Wall Clearance-All Models

 

 

Figure 6

 

 

1.

Top baffle fills the total area above the refrig-

2

2

 

erator an is properly aligned with the side wall

 

 

 

construction.

 

 

2.

0 - 1/2 inch at the sides of the refrigerator.

 

 

Figure 6

7

Page 7
Image 7
Norcold 483, 463 Side Wall Clearance - Figure, Upper Side Wall Exhaust Vent For Mod, els 452, 453, 442, and 443 ONLY