NOTES |
|
|
|
|
| 3 SPEED |
|
|
|
|
|
|
|
|
|
|
|
| HEATING/COOLING | |||||||||||
|
|
|
|
| BLOWER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
1. Incoming power must be polarized. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
HEATING/ |
|
|
|
|
| MOTOR |
|
|
|
|
|
|
|
|
|
|
|
|
| BLOWER |
| |||||||||
Observe color coding. (See furnace |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUX. LIMIT |
| MOTOR |
| |||||
data label for electrical information.) | COOLING |
| (HIGH)BLACK |
| (MED.BLUEHI) |
|
| (LOW)RED | WHITE | W |
|
|
| 4 SPEED |
| |||||||||||||||
|
|
|
|
|
|
|
| BLUE |
| LO) |
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
2. If any of the original wires (as supplied |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| G |
|
|
|
|
| |||||
with the appliance) must be replaced, |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
| (LOW)RED (HIGH)BLACK | (MED.BLUEHI) (MED.ORANGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GRAY RED GREEN WHITE | WHITE | ||||||||||
use 105˚C Thermoplastic type wire or |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C | ||||||||||
its equivalent. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
CONNECTOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| HOUSING CAP | 1 |
| 2 |
| 3 | 4 | 5 |
| 6 |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 2 3 4 5 6
| TIE WIRE |
|
|
|
|
|
|
|
|
|
| |
| ON/OFF |
|
| RED |
| WHITE |
|
|
|
|
|
|
| SWITCH |
|
|
|
|
|
|
|
|
| ||
|
|
| BLACK |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| BLUE |
|
|
|
|
| BLUE |
|
|
|
|
|
| BLUE |
|
|
|
|
|
|
| |
BLACK | BLACK |
|
|
| RED | FUSE |
|
|
|
|
| |
4 | 6 |
| GRAY |
|
|
| ||||||
|
| 3 COMBUSTION |
|
|
|
|
|
|
| |||
|
|
|
| BLOWER |
|
|
|
|
|
|
| |
|
| 2 | 5 | 1 RELAY |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 3A |
|
| FAN |
|
|
|
| BLACK |
|
|
| BLACK | SWITCH |
|
| |||
|
|
|
| GRAY |
| GRAY |
|
| GREEN |
|
|
|
|
|
|
| BLACK | TRANSFORMER | 1 | 2 | COMBUSTION FAN | ||||
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| 24 V |
| ||||
|
|
|
|
|
| R |
| C |
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||
SUPPLIED | RED* |
|
| ORANGE | L1 |
|
| N |
|
| CONNECTOR | |
BY INSTALLER |
|
|
| 115 V |
|
| HOUSING | |||||
|
|
|
|
|
|
|
|
| ||||
|
| 4 | 6 | 3 | GREEN |
|
|
| WHITE |
|
|
|
|
|
|
|
| WHITE |
|
|
| ||||
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
L1 | A/C | 2 | 5 | 1 |
|
|
|
|
|
|
| PRESSURE |
NEUTRAL | BLOWER |
|
|
|
|
|
|
|
|
| ||
RELAY |
|
|
| ORANGE |
|
|
|
|
|
| SWITCH | |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| BLACK |
|
|
|
|
| WHITE |
|
|
|
|
| BLACK |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
GROUND |
|
|
|
| GRAY |
|
|
| BLUE |
|
|
|
SCREW |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FURNACE ELECTRICAL BOX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| * Jumper Wire - M1GB 090 Units Only | A/C & Heating Speeds: Refer to | |
|
|
|
|
|
|
|
|
|
|
|
|
| |||
LEGENDS |
|
|
|
|
|
|
|
|
|
| Otherwise | Table 10, A/C Blower Selection | |||
|
|
|
|
|
|
|
|
|
| ||||||
115V: |
| FIELD 115V: |
|
|
|
|
|
|
| GAS | to Blower Relay (Black) | in the manual | |||
|
|
|
|
|
|
|
|
| |||||||
24V: | FIELD 24V: |
|
|
|
|
|
|
| - M1GB 077 Heating: Orange wire |
|
| ||||
|
|
|
|
|
|
| VALVE |
|
| ||||||
|
|
|
|
|
|
|
|
|
| replaced by Blue | 710151 08/00 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| - M1GB 090 Heating: Orange wire | ||
|
|
|
|
|
|
|
|
|
|
|
|
| replaced by Black |
|
|
37
Figure 43. Standing Pilot with Induced Draft Furnace, A/C Ready M1G (B, C, D) 077, 090 Models