21. EQUIVALENT ORIFICE SIZES AT HIGH ALTITUDES

(Includes 4% Input Reduction for Each 1,000 Feet)

FURNACE

ORIFICE SIZE AND

 

 

 

 

ALTITUDE - FEET

 

 

 

MODEL

OUTPUT CAPACITY

SEA LEVEL

2000

3000

4000

5000

6000

7000

8000

9000

10000

 

ORIFICE SIZE - NAT. GAS

29

29

30

30

30

30

31

31

31

32

M1M/G 056

ORIFICE SIZE - LP

45

46

47

47

47

48

48

49

49

50

 

OUTPUT- MBTUH

45.4

41.8

40.1

38.5

37.0

35.5

34.1

32.7

31.4

30.2

 

ORIFICE SIZE - NAT. GAS

24

25

26

27

27

28

28

29

29

30

M1M/G 070

ORIFICE SIZE - LP

42

42

43

43

43

44

44

45

46

47

 

OUTPUT- MBTUH

56.7

52.3

50.2

48.2

46.2

44.4

42.6

40.9

39.3

37.7

 

ORIFICE SIZE - NAT. GAS

21

23

23

24

25

26

27

28

28

29

M1M 077

ORIFICE SIZE - LP

40

41

42

42

42

43

43

44

44

45

 

OUTPUT- MBTUH

61.7

56.9

54.6

52.4

50.3

48.3

46.4

44.5

42.7

41.0

 

ORIFICE SIZE - NAT. GAS

21

23

23

24

25

26

27

28

28

29

M1G 077

ORIFICE SIZE - LP

40

41

42

42

42

43

43

44

44

45

 

OUTPUT- MBTUH

59.9

55.2

53.0

50.9

48.9

46.9

45.0

43.2

41.5

39.8

 

ORIFICE SIZE - NAT. GAS

17

18

19

19

20

21

22

23

24

26

M1M 090

ORIFICE SIZE - LP

36

37

38

38

39

40

41

41

42

43

 

OUTPUT- MBTUH

71.7

66.1

63.5

60.9

58.5

56.1

53.9

51.7

49.7

47.7

 

ORIFICE SIZE - NAT. GAS

17

18

19

19

20

21

22

23

24

26

M1G 090

ORIFICE SIZE - LP

36

37

38

38

39

40

41

41

42

43

 

OUTPUT- MBTUH

69.7

64.2

61.7

59.2

56.8

54.6

52.4

50.3

48.3

46.3

 

ORIFICE SIZE - NAT. GAS

26

27

28

28

28

29

29

30

30

30

M1B 066

ORIFICE SIZE - LP

43

44

44

44

45

45

46

47

47

48

 

OUTPUT- MBTUH

52.6

48.5

46.6

44.7

42.9

41.2

39.6

38.0

36.5

35.0

 

ORIFICE SIZE - NAT. GAS

18

19

19

20

21

22

23

24

26

27

M1B 086

ORIFICE SIZE - LP

37

38

39

39

40

41

42

42

43

43

 

OUTPUT- MBTUH

68.2

62.9

60.3

57.9

55.6

53.4

51.2

49.2

47.2

45.3

Table 12. High Altitude

Reference Sources: ANSI Z233.1 & NFPA 54, National Fuel Gas Code.

For Canadian high altitude (2,000 - 4,500'), reduce gas manifold pressure to 3.0” W.C. for

natural gas and 9” W.C. for LP gas.

NOTE: Do not attempt to change the size of an orifice by drilling it out. To do so will void the manufacturer’s warranty

INSTALLER: Please leave these installation instructions with the homeowner.

¢708672;¤

O’Fallon, MO

7086720

7086720 (Replaces 708074E)

Specifications and illustrations subject to change without notice and without incurring obligations.

Printed in U.S.A. (12/06)
Page 40
Image 40
Nordyne M1G Equivalent Orifice Sizes At High Altitudes, ¢708672¤, Includes 4% Input Reduction for Each 1,000 Feet, 7086720