11. INSTALLATION

Required floor, ceiling, and roof cut-out open- ings must be carefully located to avoid misalign- ment of the furnace and Roof Jack (see Figures 12 & 13). Installation procedures are suggested for typical furnace installations and need not be followed in the exact listed sequence.

CUT OUT FLOOR OPENING & FUEL LINE HOLE

a. Determine center of closet or alcove (Figure 13).

b.Locate center of the floor opening, measured 10" from the rear wall, and mark cut-out measuring approximately 14-1/2" by 14-1/2" (± 1”) for model duct connector used (refer to Figures 10 & 11).

c.Locate center of fuel line hole, measured 23- 1/4" from the rear wall and 6-5/8" to the left of center of the floor cut-out (See Figure 12) or

5-1/4" to the left of center of the floor cut-out, or for entry through right-side of furnace measured 9" to the right of center of the floor cut-out.

d. Cut out floor opening and one fuel line hole.

!IMPORTANT:

Refer to the installation instructions provided with optional air conditioning packageswheninstallingfurnaceswith optional cooling coil cabinet or with optional C***-series indoor coils.

CUT OUT CEILING AND ROOF OPENINGS a. Locate center of Roof Jack opening, mea- sured 13 1/2" from the rear wall of closet or alcove along the center line of furnace and

floor opening. (See Figure 13)

MOUNTING

REAR WALL

PLATE

 

FLOOR

OPENING

FUEL

LINE

HOLES

SUPPLY AIR DUCT

CUT DUCT OPENING 1/16TH. LARGER THAN DUCT CONNECTOR

Figure 14. Mounting Plate

 

MOUNTING

SCREWS

 

 

UNDER DUCT OPENING

PLATE

 

 

 

MOUNTING

DUCT

 

CONNECTOR

 

PLATE

 

 

 

FLOOR

 

 

OPENING

 

 

FUEL

 

FUEL

LINE

 

 

LINE

HOLES

 

 

HOLES

 

 

SUPPLY AIR DUCT

 

 

Non-Platinum Series

Platinum Series

14” SUPPLY

CONNECTION

Figure 15. Duct Connector

11