Nordyne M1B Installation Standards, Blower / Motor Assembly, A/C Capacity, Blower Wheel, Motor-Hp

Models: M1M M1S M1B M1G

1 40
Download 40 pages 21.44 Kb
Page 5
Image 5
Part No.

Part No.

Blower / Motor Assembly

A/C Capacity

Blower Wheel

Motor-Hp

Ton

 

903773

10 x 8

1/4

2, 2½ & 3

903413

11 x 8

1/2

2, 2½, 3 & 4

903414

11 x 8

3/4

2, 2½, 3, 4 & 5

Table 3. Field Installation Blower Assemblies

Carefully review these responsibilities with your manufactured housing dealer, service com- pany or gas supplier so there will be no misun- derstanding at a later time.

 

! CAUTION:

Never attempt to alter or modify this

 

furnace or any of its components.

Never attempt to repair damaged or

 

inoperable components. Such action

 

could cause unsafe operation, explo-

 

sion, fire and/or asphyxiation.

If a malfunction has occurred, or if

6" (152 mm)

Top Clearance

0" Side Clearance to Furnace Cabinet

Removable access panel should be installed above furnace door frame to access roof jack

18"

 

(457

mm)

Nearest

 

 

Wall or

Partition

you feel that the furnace is not oper-

ating as it should, contact a qualified

Figure 2. Alcove Installation

service agency or gas utility for as-

sistance.

4.INSTALLATION STANDARDS

Installer shall be familiar with and comply with all codes and regulations applicable to the instal- lation of these heating appliances and related equipment. In lieu of local codes, the installation shall be in accordance with the current provi- sions of one or more of the following standards.

6" (152 mm)

Top Clearance

0" Side Clearance to Furnace Cabinet

Provide min. 235 sq. in. (1516 cm 2 ) open free area in front or side wall

or

In closet door

located at top, center

or bottom

(152

6"

mm)

 

CLOSET DOOR

Figure 3. Closet Installation

“A”- 56"

 

“A” Model-

“B”- 76"

w/o Coil Cabinet

 

“B” Model-

 

w/Coil Cabinet

 

23 3/4"

19 3/4"

6" (152 mm)

Top Clearance

0" Side Clearance to Furnace Cabinet

Provide min. 250 sq. in. (1613 cm 2) open free area in front or side wall

or

in closet door

a fully louvered door may be used

(25

1"

mm)

 

CLOSET DOOR

Figure 1. Overall Dimensions

Figure 4. Special 1” Clearance

5