Blower Speed Selection Chart for M1*B Models and
for use with Blower Kit No. 903773 | 1/4 Hp | 3 Speed | |||
| Heating | Cooling Speed/ Evap Coil | |||
Furnace Input | Speed |
|
|
|
|
2 Ton |
| 3 Ton | |||
| Setting | Ton |
| ||
|
|
|
| ||
|
|
|
|
|
|
086, 090 | H | L | M |
| H |
|
|
|
|
|
|
066, 070, 077 | M | L | M |
| H |
056 | L | L | M |
| H |
Blower Speed Selection Chart for M1*C Models and |
| ||||
for use with Blower Kit No. 903413 | 1/2 Hp | 4 Speed |
| ||
| Heating | Cooling Speed/ Evap Coil | |||
|
|
|
|
|
|
Furnace Input | Speed | 2 Ton | 4 Ton | ||
Setting |
| & 3 Ton | Ton |
| |
077, 086, 090 | ML | L | ML | MH | H |
056, 066, 070
L
L
ML
MH
H
Blower Speed Selection Chart for M1*D Models and for use with Blower Kit No. 903414 and 903890
3/4 Hp 4 Speed
| Heating | Cooling Speed/ Evap Coil |
| ||
Furnace Input | Speed | 2 Ton | |||
| Setting |
| & 3 Ton | & 4 Ton |
|
077, 086, 090 | ML | L | ML | MH | H |
056, 066, 070
L
L
ML
MH
H
Table 11. A/C Blower Selection
The furnace must also be equipped with an automatic damper (See Figures 37 or 38, NORDYNE p/n 901996 for furnaces without coil cavity, or p/n 901083 with coil cavity) to prevent cold air from being discharged up around the heat exchanger. Cold air may cause conden- sation inside the heat exchanger which can lead to rust and early failure.
OPTIONAL
Listed and ARI Certified, all models are pro- tected by the NORDYNE Air Conditioner Lim- ited Warranty.
Platinum series units are self contained pack- age units with compressor and cooling coils. They are designed as a drop in system when used with the AC ready M1.
Single package unit includes cooling coils, com- pressor, and vertical discharge fan. This type of unit connects with the existing home air duct system (an optional
Split system unit with vertical discharge for quiet operation connects with NORDYNE cooling coil furnace (optional coil cavity required with “A” model furnaces).