BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes

CR 106129: ATM

The router incorrectly determines specific 802.5 MAC addresses as broadcasts when processing LE_ARP responses. This causes the LEC to restart.

CR 107143: ATM

The router is not responding to LE_ARP destined for it's own MAC address on

802.5elans. This condition affects performance because the router sends unnecessary traffic to other LECs and creates congestion on the bus.

CR 107164: Frame relay

Bus errors occur on the FRE processor before it goes into diag mode when you bring down a frame relay interface with an HSSI card configured with IP. This occurs whenever the router brings down the frame relay interface after not receiving the LMI status messages.

CR 107581: BGP

BGP is not advertising and withdrawing correctly when handling two announcements of the same network to two different peers.

CR 107675: DVMRP

When a non-dominant router becomes the dominant router and subordinate routers are contained in its loop neighbor list, the newly dominant router will not graft traffic.

CR 107703: IGMP

Multicast data packets gets duplicated on a DVMRP router where MTM has outbound cache entry on an inbound circuit.

CR 107811: ATM

A memory leak occurs on the ATM interface after a virtual circuit is repeatedly brought up and then killed using the Technician Interface.

CR 107938: ATM

The router does not clean up the ATM circuit when a port is dynamically deleted using Site Manager.

305279-C Rev 00

1-11

Page 19
Image 19
Nortel Networks 13.03 manual Rev