BayRS Version 13.03 and Site Manager Software Version 7.03 Release Notes

CR 103342: Technician Interface

Running readexe bn.exe on a single-slot ARE BLN can cause a VBM error to occur if the More option is set to On and there is no session activity for 10 seconds.

CR 103355: X.25

Receipt of a disconnect request in TCP retry mode causes an IPEX gateway bus error.

CR 103570: DLSw/SDLC

Bus errors occur when you bounce DLSw on SDLC to SDLC pu2.0 point-to-point setup.

CR 103944: VINES

VINES is sending ping responses with a calculated hop count rather than a max hop count. This causes packets to be zero-hop dropped on the return whenever there are multiple equal-cost paths with different hop counts.

CR 104133: DLSw

Resetting the slot on SDLC to SDLC setup with DLSw 2.0 may cause bus errors to occur.

CR 104366: Flash

Compacting an already compacted 40 MB flash card on a FRE-2, FRE-2_060, or ARE causes a watchdog error to occur.

CR 104948: ATM

The router inserts multiple entries in the LE_ARP table, which causes watchdogs when reverifying entries in the LE_ARP table. The router also does not bitswap MAC addresses before sending out LE_ARPs when reverifying 802.5 clients.

CR 105130: Technician Interface

An unauthorized operator can use the partition create and partition delete commands, which should be restricted to Manager access only.

1-8

305279-C Rev 00

Page 16
Image 16
Nortel Networks 13.03 manual Rev