MZ-B10
If the [GROUP] key or the [DISPLAY] key on the remote com- mander is pressed with this display, the LCD switches to the simple display mode.
4.Quit the
• Description of Error Indication Codes
x
key
Problem |
| Indication code |
| Meaning of code | Simple display | Description | ||
|
|
|
|
|
|
| ||
No error |
| 00 |
| No error | No error | |||
|
|
|
|
|
|
|
| |
|
|
| 01 |
| Illegal access target | Adrs | Attempt to access an abnormal address | |
|
|
|
| address was specified | ||||
|
|
|
|
|
|
| ||
Servo system error |
| 02 |
| High temperature | Temp | High temperature detected | ||
|
|
|
|
|
|
|
| |
|
|
| 03 |
| Focus error | Fcus | Disordered focus or can not read an address | |
|
|
|
|
|
|
|
| |
|
|
| 04 |
| Spindle error | Spdl | Abnormal rotation of disc | |
|
|
|
|
|
|
|
| |
|
|
| 11 |
| TOC error | TOC | Faulty TOC contents | |
|
|
|
|
|
|
| ||
TOC error |
| 12 |
| Data reading error | Data | data could not be read at SYNC | ||
|
|
|
|
|
|
|
| |
|
|
| 13 |
| TOC address error | Tadr | TOC address data error | |
|
|
|
|
|
|
| ||
Power supply system error |
| 22 |
| Low battery | LBat | Momentary interruption detected | ||
|
|
|
|
|
|
|
| |
|
|
| 31 |
| Offset error | Ofst | Offset error | |
|
|
|
|
|
|
|
| |
|
|
| 32 |
| Focus error ABCD | ABCD | Focus error ABCD offset error | |
|
|
|
| offset error | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Offset system error |
| 33 |
| Tracking error | TE | Tracking error Offset error | ||
|
| Offset error | ||||||
|
|
|
|
|
|
| ||
|
|
| 34 |
| X1 tracking error | X1TE | X1 tracking error Offset error | |
|
|
|
| Offset error | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| 35 |
| MD DATA 2 | MD2 | MD DATA 2 disc error | |
|
|
|
| disc error | ||||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
| 36 |
| Mirror error | Mirr | Mirror retry over | |
• Description of Indication History |
|
|
|
| ||||
|
|
|
|
|
|
| ||
History code number |
|
| Description |
|
|
| ||
|
|
|
|
|
|
|
|
|
1 |
| The first error |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
N |
| The last error |
|
|
|
| ||
|
|
|
|
|
|
|
| |
N1 |
| One error before the last. |
|
|
| |||
|
|
|
|
|
|
|
| |
N2 |
| Two errors before the last. |
|
|
| |||
R_ |
| Total recording time |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
Reset the Error Display Code
After servicing, reset the error display code.
•Setting Method of Reset the Error Display Code
1. Set the test mode (see page 15).
2. Pressing the [GROUP] key or pressing the [DISPLAY] key on the remote commander activates the
3. To reset the error display code, press the X key (twice) when the code is displayed (except “R_****”).
(All the data on the 1, N, N1, and N2 will be reset)