Laser Power Check
Note: If result of measurement of the laser power does not satisfy the specification, either replace the OP (optical
• Connection
laser
power meter
optical
• Checking method
1.Select the manual mode of test mode (see page 16), and set the laser power check mode (item number 010).
Set LCD display
Laser
010
2. | Press the | . | key continuously until the optical |
| moves to the most inward track. | ||
3. | Open the cover and set the laser power meter on the objective | ||
| lens of the optical |
MZ-B10
Ver 1.1 2003.06
9.Check that the laser power meter reading is 4.95 ± 0.59 mW.
10.Press the > key, and set the laser MO (X4 speed) write check mode (item number 014). Modify the adjusted value to 9E with the [SPEED CONTROL +] or [SPEED CONTROL -
Set LCD display
WrPwHi 9E
014
9E: Initial value
11.Check that the laser power meter reading is 5.93 ± 0.71mW.
12.Press the x key to quit the manual mode, and activate the test mode (display check mode).
Overall Adjustment Mode
• Configuration of Overall Adjustment Mode
Overall adjustment mode | x key | |||||||
(Title display) |
|
|
|
| ||||
|
|
|
| |||||
"Assy**" |
|
|
|
| ||||
|
|
|
|
| Continuing overall adjustment | |||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| key |
|
|
|
|
|
|
| . |
|
| CD overall |
| |
|
|
|
|
|
|
|
| |
|
|
|
| key |
|
| adjusting |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
| > |
|
| MO overall |
| |
|
|
|
|
| ||||
|
|
|
|
|
|
| adjusting |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
4. Press the > key, and set the laser MO read check mode |
(item number 011). |
Set LCD display
LrefPw 16
011
Nkey or
u key
on the remote commander
[SPEED CONTROL +] key or [DISPLAY] key
on the remote commander
Automatic
Disc
discrimination
overall
adjustment
Electrical
offset
adjustment
16: Initial value
5.Check that the laser power meter reading is 0.800 ± 0.10 mW.
6.Press the > key, and set the laser CD read adjustment mode (item number 012). Modify the adjusted value to 18 with the
[SPEED CONTROL +] or [SPEED CONTROL
Set LCD display
HrefPw 18
012
18: Initial value
7.Check that the laser power meter reading is 0.910 ± 0.11 mW.
8.Press the > key, and set the laser MO (X2 speed) write check mode (item number 013). Modify the adjusted value to 85 with the [SPEED CONTROL +] or [SPEED CONTROL -
Set LCD display
WrPwLo 85
013
85: Initial value
[SPEED CONTROL
on the remote commander
[GROUP] key or
key
on the remote commander
Temperature
correction
and
Power supply
adjustment
auto item feed
NV reset
(item number 21)
27