Sound Skip Check Result Display Mode

This set can display the count of errors that occurred during the recording/playing for checking.

Setting Method of Sound Skip Check Result Display Mode

1.Set the test mode (see page 15).

2.Press the N key or [REC] key, and the playing or recording sound skip result display mode becomes active respectively where the LCD displays the following.

Set LCD display

P**R**

 

 

 

 

 

 

Total count of record

 

 

 

 

 

 

 

 

 

000

system errors (hex.)

 

 

 

 

 

 

Total count of play

 

 

 

 

 

 

 

 

 

 

 

 

system errors (hex.)

3.When the N key is pressed, total error count is displayed on the LCD, and each time the > key is pressed, the display item moves down by one as shown below. Also, if the . key is pressed, the display item moves up by one, then if the [REC] key is pressed, the display in the record mode appears.

When the [REC] key is pressed, total error count is displayed on the LCD, and each time the > key is pressed, the dis- play item moves down by one as shown below. Also, if the . key is pressed, the display item moves up by one, then if the N key is pressed, the display in the play mode appears.

Playing sound skip

Recording sound skip

result display

result display

MZ-B10

• Cause of Sound Skip Error

 

Cause of error

Description of error

 

 

 

 

EIB

Sound error correction error

 

 

 

Play

Stat

Decoder status error

 

 

Adrs

Address access error

 

 

BEmp

Buffer is empty

 

 

 

 

BOvr

Buffer is full, and sounds were

 

dumped

 

 

 

 

 

Record

Bful

Buffer capacity becomes less,

 

and forcible writing occurred

 

 

 

 

 

 

Rtry

Retry times over

4.To quit the sound skip check result display mode and to return to the test mode (display check mode), press the x key.

• Setting Method of Key Check Mode

1.Set the test mode (see page 15).

2.Pressing the [TRACK MARK]key activates the key check mode.

Set LCD display

**

000

3.When each key on the set and on remote commander is pressed, its name is displayed on the set LCD. (Operated position is displayed for 4 seconds after the slide switch is operated.

Example: When the > key on the set is pressed:

Set LCD display

P**R**

000

EIB **

000

Stat**

000

Adrs**

000

BEmp**000

######000

P**R**

000

BOvr**

000

Bful**

000

Rtry**

000

######000

FF **

000

4.When all the keys on the set and on the remote commander are considered as OK, the following displays are shown.

Example: When the keys on the set are considered as OK:

Set LCD display

SET OK **

888

5.When the upper panel is opened, the key check mode quits and the test mode (display check mode) comes back.

P**R**: Total play/record errors (hex.)

**: Counter of sound skip check each item (hex.)

######: 6-digit address where sound was skipped last (hex.)

19

Page 19
Image 19
Sony MZ-B10 service manual EIB Stat Adrs BEmp**000 ######000 BOvr Bful Rtry, 888, Sound Skip Check Result Display Mode