MZ-B10
• Overall Adjustment Mode (Title Display)
Set LCD display
Assy**
000
: (Disc mark) At end of power supply adjustment: Outside lit
**: Left side = MO overall adjustment information F*: MO overall adjustment completed
1*: Manual adjustment exists (overall adj. not completed)
0*: Not adjusted
Right side = CD overall adjustment information *F: CD overall adjustment completed
*1: Manual adjustment exists (overall adj. not completed)
*0: Not adjusted
Note: Adjust the CD first, when performing adjustment.
•Adjustment Method of CD and MO Overall Adjustment Mode
1.Set the test mode (see page 16).
2.Press the . key or press
Set LCD display
Assy11
000
3.Insert CD disc in the set, and press the . key to set the CD overall adjustment mode. Automatic adjustments are made.
Set LCD display
CD RUN
XXX
XXX: Item number for which
an adjustment is being executed.
4.In case of CD overall adjustment NG, readjust from the NV reset (see page 20), The temperature correction (see page 20) may be omitted.
Set LCD display
***NG
000
***: NG item number.
5.If OK through the CD overall adjustments, then perform MO overall adjustments.
Set LCD display
CD OK
000
6.Insert MO disc in the set, and press the > key to set the MO overall adjustment mode. Automatic adjustments are
made.
Set LCD display
MO RUN
XXX
XXX: Item number for which
an adjustment is being executed.
7.In case of MO overall adjustment NG, readjust from the NV reset (see page 21). The temperature correction (see page 20) may be omitted.
Set LCD display
***NG
000
***: NG item number.
8.If OK through the MO overall adjustments, press the x key to return to the test mode and terminate the overall adjustment mode.
Set LCD display
MO OK
000
• Overall Adjustment error message
The following message will be displayed if adjustment procedure is mistaken in the CD and MO overall adjustment.
Message | Display timing | Description | |
|
|
| |
| During CD/MO/DISC |
| |
CLOSE! | automatic distinction | DISC is not inserted. | |
| overall adjustment |
| |
|
|
| |
|
| • CD overall adjustment is not | |
| During MO/DISC | completed in the MO overall | |
Set CD! | automatic distinction | adjustment. | |
overall adjustment | • CD and MO overall | ||
| |||
| During offset adjustment | adjustment is not completed | |
|
| in the offset adjustment. | |
|
|
| |
|
| MO overall adjustment is not | |
Set MO! | During offset adjustment | completed in the offset | |
|
| adjustment | |
|
|
| |
| During CD/MO/DISC | Temperature correction | |
NoTmp! | automatic distinction | (item number 015) | |
| overall adjustment | is not finished. | |
|
|
|
28