These physical interfaces are separated into the logical interfaces from FIPS as described in the following table:

Switch physical interface

FIPS 140-1 Logical Interface

 

 

10/100BASE-TX LAN Port,

Data Input Interface

LAN Port,

 

Serial Port

 

10/100BASE-TX LAN Port,

Data Output Interface

LAN Port,

 

Serial Port

 

Power Button,

Control Input Interface

Reset Button,

 

Serial Port,

 

LAN Port

 

LAN Port LEDs,

Status Output Interface

10/100BASE-TX LAN Port LEDs

 

Serial Port

 

Power Button Light

 

Reset Button Light

 

Dual Power Plugs

Power Interface

Table 1 – FIPS 140-1 Logical Interfaces

2.3Redundancy and Physical Security

With up to 5,000 simultaneous users accessing critical information, network managers can rest assured that the Contivity Extranet Switch is designed for high availability. Auto switching redundant power supplies and a redundant storage system protect against failure. Multilevel authentication methods and automatic backup of all system and accounting data ensure maximum reliability and management peace of mind. The Switch meets FCC requirements in 47 CFR Part 15 for personal computers and peripherals designated for business use (ClassA), and is labeled in accordance with FCC requirements.

The Contivity™ Extranet Switch 4500 is entirely encased by a thick steel chassis. The system has three removable portions: the front bezel, the top cover, and the I/O Panel. Removing the

© Copyright 2000 Nortel Networks.

7

Page 7
Image 7
Nortel Networks 4500 FIPS manual Redundancy and Physical Security, 10/100BASE-TX LAN LEDs, Switch physical interface