9158FA

9159FA

7.Connect the power cord to the power supply and to a power outlet that is on a circuit with no other equipment connected to it.

Connect each power supply in the chassis to a separate AC circuit.

8.Turn on the power switch.

Note: In a chassis that requires two power supplies (nonredundant configuration), you must turn on both units within 2 seconds of each other. If you wait longer to turn on the second power supply, both power supplies will latch off. To correct this condition, turn off both power supplies, wait at least 30 seconds, and turn both power supplies on again within 2 seconds.

Specifications

Input current (maximum)

12 to 6 A

Input voltage

100 to 240 VAC

Line Frequency

47 to 63 Hz

Power consumption

1112 W

Thermal rating

3792 BTU/hr maximum

5

Page 7
Image 7
Nortel Networks 8001PS manual Specifications