Electrical Specifications

 

System Line Frequency

47 to 63 Hz

System with one power supply or two supplies in redundant configuration:

Input Volt Amperes Rating: 1,236 VA maximum

Input Power: 1,112 W maximum

Input Voltage: 100-240 VAC

Input current: 12 to 6 A per line cord

Thermal rating: 3,792 BTU per hour maximum

System with two power supplies (nonredundant) or three supplies in redundant configuration:

 

Input Volt Amperes Rating: 2472 VA maximum

 

Input Power: 2224 W maximum

 

Input Voltage: 100-240 VAC

 

Input current: 12 to 6 A per line cord

 

Thermal rating: 7584 BTU per hour maximum

Electromagnetic Immunity

 

RF Susceptibility:

IEC801-3, Level 2

Electrostatic discharge (ESO):

IEC801-2, Level 2/3

Electrical Fast Transitions (EFT/B):

IEC801-4, Level 1/2

Electromagnetic Emissions

 

Meets requirements of:

(USA) FCC CFR 47 Part 15, Subpart B, Class A

 

(Canada) ICES-003, Issue-2, Class A

 

(Australia/New Zealand) AS/NZS 3548:1995, Class A

 

(Japan) VCCI V-3/97.04, Class A

 

(Taiwan) CNS 13438, Class A

 

EN 55 022 (CISPR 22:1985), Class A

 

CE Mark

Safety Agency Approvals

 

UL Listed

 

CUL Approved

 

CB report and certificate

 

NOM Approved

 