Start LPG/NG supply

Operation (cont’d)

Start LPG/NG supply

(if using)

Always dissipate static charge from your body before beginning the fueling process by touching a grounded metal object at a safe distance from fuel sources.

Never fill the generator’s gas tank directly from the fuel pump – the generator’s tank is not grounded and high velocity flow from the pump can cause static electricity build-up. Use an approved portable container to transfer gas to the generator’s tank.

Never fill the portable gas container while it is sitting inside a vehicle, trailer, trunk, or pick-up truck bed. ALWAYS place container on the ground to be filled.

Keep nozzle in contact with portable container while filling. Manually control the flow of gasoline; do NOT use nozzle’s lock- open device.

A portable container made of metal or conductive plastic is preferred because it dissipates charge to ground more readily.

5)Clean up gasoline spills /splashes immediately.

If possible, move the generator away from spilled gasoline on the ground.

Wipe up spilled gasoline, and wait 5 minutes for excess gasoline to evaporate before starting engine.

Gasoline soaked rags are flammable and should be disposed of properly.

If gasoline is spilled on your skin or clothes, change clothes and wash skin immediately.

6)Replace gasoline cap securely before starting engine.

7)Store extra gasoline in a cool, dry place in an UL-approved, tightly sealed container.

IMPORTANT:

For continuous operation, be prepared to check and refuel the engine on a regular basis. A tank of gasoline should last about 4 hours under 100% load, and about 8 hours under 50% load.

Propane (LPG):

1)Make sure the fuel hose is securely connected to the propane tank regulator on one end, and the ¾” NPT gas inlet on the generator base on the other end.

2)Open the propane tank main valve.

3)Check ¾” NPT gas inlet connection for leaks each time you connect. Use the leak test method described below.

Natural Gas:

1)Make sure the gas line is securely connected to the ¾” inlet on the generator base.

2)Open line valve, if gas line is so equipped.

3)Check ¾” NPT gas inlet connection for leaks each time you connect. Use the leak test method described below.