North Star M165938N owner manual Preparing for Operation, Position generator Ground generator

Models: M165938N

1 48
Download 48 pages 27.98 Kb
Page 26
Image 26
Position generator

Operation (cont’d)

Position generator

Ground generator

Perform scheduled maintenance as needed

Check/add oil

2. Preparing for Operation

Position generator in accordance with the instructions given in “Installation & Initial Set-up, Step 5: Select a Suitable Site” of this manual.

Operate outside only, on dry, level ground with adequate clearance and ventilation.

Perform scheduled maintenance as needed2. Preparing for Operation WARNING: Carbon monoxide poisoning hazard

Generators give off carbon monoxide exhaust, a poisonous gas that can kill. You CANNOT smell it, see it, or taste it. ONLY run generator OUTDOORS and away from air intakes. NEVER run generator inside any enclosed or semi-enclosed spaces, including homes, garages, basements, sheds, boxes, pick-up truck beds, RVs, or boats. These spaces can trap poisonous gases, EVEN if you run a fan or open windows. Carbon monoxide exhaust is given off whether you are using gasoline, natural gas, or propane to power the generator.

Make sure the generator is grounded in accordance with instruction given in “Installation & Initial Set-up, Step 6: Grounding the Generator” of this manual.

 WARNING: Electric shock hazardCheck the oil level using the dipstick and add oil as needed. WARNING: Burn hazardoEngine is shipped without oil. You must add oil before first use. WARNING: Electric shock hazard

Always ensure generator is properly grounded to prevent electrical shock.

Make sure that any regular maintenance has been performed as prescribed in this manual in the “Maintenance & Repair” section.

1.Refer to the engine owner’s manual for engine maintenance instructions.

2.Make sure battery is charged. Charge as needed according to your battery manufacturer’s instructions.

Check the oil level using the dipstick and add oil as needed.

Using a funnel, add oil up to the FULL mark on the dip stick with the recommended oil type for your engine and expected ambient conditions. (See engine Owner’s Manual for oil type and capacity, and more detailed oil check/fill instructions.)

Manual backgroundManual background WARNING: Burn hazard

Never open oil port while engine is running. Hot oil can spray over face and body.

Notes:

oLow oil shutdown feature prevents the generator from starting without sufficient oil.

oEngine is shipped without oil. You must add oil before first use.

IMPORTANT:

Under long, continuous-run operating conditions, be prepared to:

Check engine oil level every time you refuel the engine if using gasoline, or every 24 operating hours if using NG/LPG.

Change oil after the first 20 operating hours, and at least every 100 operating hours thereafter, or as directed in engine owner’s manual.

26

Page 26
Image 26
North Star M165938N Preparing for Operation, Position generator Ground generator, WARNING Electric shock hazard