NM200 Master station Installation

Gather all remote station and door station cables and cut cable ends to the same length approximately 12 inches from entry point into master rough-in. Make sure that all cables remain properly labeled. Strip approximately 2” of jacket from each of the CAT5 cables. Untwist the individual wire pairs. Insert each wire pair into the correct connector location and close connector. Please see figure below. Insert each cable connector into its proper location on the NM200 master.

Make sure that the outdoor remote station is connected into the outdoor remote stations cables location only. If you are connecting two outdoor remote stations, use the screw terminal connectors provided with the NPS200 for the outdoor remote station. Connect both outdoor remote stations cables into one screw terminal connector.

It is important to verify all cable run locations prior to connecting if they were not labeled at the rough- in. Incorrectly connecting cables to the master, remote stations or door stations may result in system damage.

Mounting the Chime Module

Install the optional NA3003C or NA3008C chime module in the master rough-in by pressing the chime module over the 4 plastic standoffs attached to the rough-in as shown. Please refer to the

Page 

If the NM200 system has more than 9 remote stations, some station selector switches will control two remote stations. Do not exceed more than 15 total speakers on the system. This limitation does not include door stations. The station location can be noted on the inside of the front access panel on the left side of the NM200 master.

Connect the red and black wires of the door station cables to the red and black door speaker terminals on the NM200 master as shown below. Insulate the bare wires using some of the jacket material to prevent shorting to the circuit board. Connect this wire to terminal labeled shield.

Connect all orange wires from the door stations to the common terminal on the NA3003C or NA3008C.

Connect each yellow wire to a note selection terminal on the NA3003C or NA3008C. Do not connect more than one yellow wire per note terminal.

Plug in the modular chime plug to the 4 pin connector labeled as CHIME on the NM200 master unit as shown.

Suspend the master unit from the master rough-in by looping the support wire assembly (thick green wire) over the hook at the top of the rough-in. Be careful not to damage the wall surface.

Page 3
Image 3
NuTone NM200WH, NM200AL installation instructions NM200 Master station Installation, Mounting the Chime Module