WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally.

INSTALL HOOD HOUSE

WIRING

(120 VAC)

CARDBOARD (Use to protect cooktop)

1 Connect House Wiring (120 VAC) to hood. Use a piece of (120 VAC) Cardboard to protect the cooktop, if necessary.

GREEN

GROUND

Manual background SCREW

2 Connect house BLACK to hood BLACK wire, house WHITE Manual background to hood WHITE wire, and house ground under GREEN Ground Screw. Securely tighten cable clamp onto house

wiring.

KEYHOLE (4)

MOUNTING SCREW (4)

1Hang hood from (4) Mounting Screws. Slide hood towards Manual background wall until mounting screws are engaged in narrow end of

(4)Keyholes. Tighten mounting screws securely. A long screwdriver works best.

2Manual background Replace bottom cover.

DUCT

TAPE

3 Connect ductwork to hood. Use Duct Tape to make joints Manual background secure and air tight.

PAR20,

50W MAX.

HALOGEN

BULB (2)

- or - R16, 40W MAX.

INCANDESCENT

BULB (2)

4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, Manual background 40 W Maximum Incandescent Bulbs. Purchase bulbs

separately.

!CAUTION: Bulbs may be hot! Refer to bulb packaging Manual background for further information.

5 Replace filters, turn on power at service panel, and test for Manual background proper operation.