Error 06 – Micropositioner Location Unknown
Possible
Cause: Micropositioner has lost servo.
Recovery
Method: Select Media/Cut and Unload. If problem persists, contact Océ.
Error 07 – Media Guide Stuck at Home
Possible
Causes:
A) Media guides are stuck in their parked position.
B) Mechanical component failure.
Recovery
Methods:
A) Select Media/Cut and Unload. Inspect media guides. Clear physical
obstruction if present.
B) Contact Océ.
Error 10 – Outfeed Timeout Fault
Possible
Cause: The bottom-of-drum sensor did not sense any media within 30 seconds.
Recovery
Method:
Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media.
If error persists, contact Océ.
Communication Failures Problems that prevent proper communication between the LightJet® 430 and the host computer
can cause total loss of communication, prevent certain functions, or corrupt the data used to
generate the image. The LightJet® 430 cannot detect:
§ Whether the host computer is unable to generate the proper commands.
§ Some cases of data corruption.1
§ When a SCSI cable is bad or disconnected.
§ When the wrong SCSI ID has been selected.2
Notes: