7 | TROUBLESHOOTING |
| |
|
|
|
|
| PROBLEM | POSSIBLE CAUSE | CORRECTION |
| LCD does not | • No power input | • Check power cord |
| light |
| connections |
|
|
| • Turn on power |
|
|
|
|
| System will not | • Foot switch not | • Check foot switch |
| actuate | plugged in or | connection |
|
| improperly plugged |
|
|
| in |
|
|
| • Defective foot switch | • Foot switch needs to be |
|
|
| repaired or replaced |
|
| • Broken wire or loose | • Unplug power cord and |
|
| connection inside | disconnect air supply. |
|
| unit | Remove cover and check |
|
|
| for broken wires or loose |
|
|
| connections |
|
| • Defective solenoid | • Replace solenoid |
|
| • Defective PC board | • Replace PC board |
| System will not | • Insufficient air | • Increase air supply |
| pressurize | pressure | pressure |
|
| • Air hoses not | • Check connection |
|
| plugged in | |
|
| • Regulator defective | • Replace regulator |
| System will not | • Vacuum setting is | • Increase vacuum setting |
| pull vacuum | too low |
|
|
| • Defective solenoid | • Replace solenoid valve |
|
| • Defective vacuum | • Replace venture |
|
| venturi |
|
|
| • Defective vacuum | • Replace needle valve |
|
| needle valve |
|
| Inconsistent | • Air bubbles in | • Reduce vacuum setting |
| dispensing | adhesive |
|
|
| • Dispense time is too | • Increase dispensing time |
|
| low |
|
|
| • Dispense needle | • Replace needle |
|
| started to clog |
|
7
8MAINTENANCE
The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following recommendations should be followed:
1.Make certain air supply is clean and dry
2.Avoid turning barrels upside down or laying barrel so that material may run through air line to internal components
3.Avoid connecting the unit to excessive moisture or solvent saturation.
4.Avoid connecting air supply exceeding 100 psi (6.9 bar) for the
5.Use only Amyl Alcohol to clean outside surface of the main housing.
6.Use only soft cloth to clean the LCD
9SPARE PARTS AND ACCESSORIES
For
10LIMITED WARRANTY
OK International warrants this product to the original purchaser for a period of one
(1)year from date of purchase to be free from material and workmanship defects but not normal
11I/O Configuration and End of Cycle Switch
For DX3xx/2xx I/O Configuration and End of Cycle Switch information, please visit the