– 23 –
2) Non-recoverable errors
Error Description POWER Lamp ERROR Lamp
Recovery Conditions
Flash access error OFF Flashes Orange
lamp at 0.5-sec-
ond intervals
This is not a recoverable error.
EEPROM error OFF Flashes
Red lamp at
0.75-second
intervals
This is not a recoverable error.
SRAM error OFF Flashes Orange
lamp at 1-sec-
ond intervals
This is not a recoverable error.
Head thermistor error OFF Flashes Red
lamp at 1.5-sec-
ond intervals
This is not a recoverable error.
Power voltage error OFF Flashes Orange
lamp at 2-sec-
ond intervals
This is not a recoverable error.
Note:
1) If a non recoverable error occurs, turn the power OFF immediately.
2) When Power supply error occurs, there is a possibility that the power supply unit has
a trouble.