Exceptional Cutting Performance and Easy,

Fast Exchange Capability for Enhanced Efficiency in ERCP Sphincterotomy

UniqueThe InnovativeDevice DesignV-SystemandDesignAttentionLetsoYouEveryProceedDetail of ThewithCleverCut2VConfidence and CleverCut3VEfficiency Sphincterotomes

The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange of

catheters, and enhances cannulation capability.

The CleverCut3V offers excellent

 

CleverCut coating enhances safety

orientation and smooth injection

 

The CleverCut3V wire, injection lumen and guidewire

 

 

 

Olympus’s signature CleverCut coating on the

lumen are arranged to allow easier orientation of the

C-Hook

cutting wire for effective sphincterotomy. Since the

 

pr ximal end of the cutting wire minimizes damage

 

to the surrounding tissue. In addition,

injection lumen and the guidewire lumen are completely

 

CleverCut Coating reduces the risk of electrical

separate, contrast media can be smoothly injected with

Now endoscopists have the option to

guidewire

 

contact between the wire and the endoscope.

manipulate guidewires and devices.

 

The convenient C-Hook allows the device handle to be attached to the

Injection

 

Features that display

 

 

the icon on the op

 

 

endoscope’s control section, putting it within easy reach of the endoscopist.

 

are available with

 

 

With the device handle right at hand, the endoscopist can maneuver the

 

CleverCut2V

 

 

double-lumen

 

 

guidewire,mod ls. inject contrast media, and manipulate the handle — all while keeping

 

Those

 

 

displaying the

control section.

 

a gripbonttomtheiconscopeare

 

available with

 

 

CleverCut3V

 

Cutting wire lumen

triple-lumen models.

 

V-Marking

Guidewire lumen

Indicates when to raise and lower the V-Groove forceps elevator.

Distal marking on the sheath for

The exclusive V-Marking is located on the proximal side of the sheath. When

this markingimprovedreachesviewthe channelfieldportvisibilityon the scope’s control section, it indicates that the device tip has reached the distal end of the scope and the V-Groove

The distal marking on the sheath

forceps elevator may be lowered. When withdrawing the device from the scope, clearly indicates both the center and

the same marking indicates when to raise the elevator to lock the guidewire. cutting position of the knife.

V-Sheath

Device control by the endoscopist or the assistant.

The V-Sheath allows the endoscopist complete device control or, if preferred, device control may be given to the assistant. The unique device design allows the guidewire sheath and injection sheath/handle to be separated. This forked sheath design allows either the endoscopist or the assistant to control the device.

 

 

 

 

 

 

 

V-System device replacement procedure

 

 

Easy identification

Sheath design for stable and

 

 

of ports

reliable cannulation

Completely remove the device.

Confirm the position of the V-Marking

When the V-Marking is completely visible

The guidewire is now locked

on the V-System EndoTherapy accessory.

above the instrument channel port, lift the

into the V-Groove.

 

 

The guidewire port and the

forceps elevator to lock the guidewire. Designed to optimize insertion into the

injection port are easily

scope, this sheath is narrower at the distal

identified by symbols.

end and thicker at the proximal end.

 

 

 

This improves handling and ensures smoother

 

insertion, while also providing excellent

 

cannulation capability into the papilla

 

 

Page 12
Image 12
Olympus StarTip V, X-Press V manual Distal marking on the sheath for