The Innovative V-System Exchange Capability Makes Olympus' ERCP Cannulae Even More Efficient

The Innovative V-System Design Lets You Proceed with Confidence and Efficiency

The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange of catheters, and enhances cannulation capability.

Excellent visibility under fluoroscopy

The platinum marking at the distal end ensures that the tip is clearly visible under fluoroscopy.

Wide selection of cannulae

A full line-up of 8 models of different tip designs and diameters is available to meet every clinical requirement.

Smooth cannulation of even minor or constricted papilla

The X-PressV’s cross-cut round tip is not only ideally suited for smooth cannulation of the papilla of Vater, but is also equally effective for cannulation of the minor or constricted papilla.

Short taper (PR-V414Q)

Standard (PR-V416Q)

Short taper (PR-V418Q)

Long taper (PR-V420Q)

Taper (PR-V434Q)

Taper (PR-V435Q)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C-Hook

Now endoscopists have the option to manipulate guidewires and devices.

The convenient C-Hook allows the device handle to be attached to the endoscope’s control section, putting it within easy reach of the endoscopist. With the device handle right at hand, the endoscopist can maneuver the guidewire, inject contrast media, and manipulate the handle — all while keeping a grip on the scope control section.

V-Marking

Indicates when to raise and lower the V-Groove forceps elevator.

The exclusive V-Marking is located on the proximal side of the sheath. When this marking reaches the channel port on the scope’s control section, it indicates that the device tip has reached the distal end of the scope and the V-Groove forceps elevator may be lowered. When withdrawing the device from the scope, the same marking indicates when to raise the elevator to lock the guidewire.

Standard position of

During guidewire

X-PressV cannula

insertion or fluid injection

Expanded guidewire compatibility

Compatible with guidewires of various sizes.

Comprehensive distal marking system

Cannulation depth is indicated by markings at 3mm intervals at the distal end.

Single-use design for convenience and reliability

All the cannulae in this line are designed for single use only.

Slit (PR-V427Q)

Ball Tip (PR-V223Q)

Page 2
Image 2
Olympus StarTip V Excellent visibility under fluoroscopy, Wide selection of cannulae, Expanded guidewire compatibility