Triple Lumen, Multi Size Balloon with

Revolutionary V-System Exchange Capability for More Precise Balloon Inflation and Efficient Stone Extraction

Reliable, Efficient Stone Extraction with the Multi-Size Balloon Design, Three Pre-Measured Syringes, and The Sheath is Manufactured from a Special Material That Allows for Easier Cannulation, Exchange and Injection of Contrast Media.

B

Multiple balloon sizing

The balloon can be inflated to one of three diameters— 8.5mm, 11.5mm, and 15mm. The balloon size can be easily adjusted to suit the requirements and conditions of each case so there is

no need to change catheters during the procedure.

Triple-lumen design allows for easy passage of the guidewire

The guidewire and injection lumens are separated to ensure smoother passage of the guidewire. Additionally, contrast media can be injected without removing the guidewire. Two models are available — one with the injection port located above the balloon and the other with the injection port located below the balloon.

Air Lumen

Injection Lumen

0.035" Guidewire Lumen

Easier cannulation

and tapered sheath design

The balloon catheter sheath is manufactured from a special material that allows it for improved insertion into the papilla, ensuring smoother guidewire passage, and facilitating contrast injection. The tapered design

7 Fr. catheter at the proximal end tapers to 5 Fr. at the distal end — enables an easy approach to the bile duct and accommodates a 0.035" guidewire.

Three pre-measured syringes for reliable inflation

Three pre-measured, clearly marked syringes enable precise inf lation of each balloon to the desired size. Much easier and much more reliable than using a single syringe with different markings,

the pre-measured syringes allow inflation of the balloon quickly and accurately without having to visually check the markings on the syringe.

The 15mm syringe also has markings at 8.5mm and 11.5mm. This makes it possible to inflate to three balloon sizes using only one syringe.(This is not pre-measured)

Dual radiopaque bands for position confirmation

For easy confirmation of balloon position during f luoroscopy, two radiopaque bands are incorporated — one at the distal end of the balloon and one at the proximal end.

Page 6
Image 6
Olympus StarTip V, X-Press V Easier cannulation Tapered sheath design, Three pre-measured syringes for reliable inflation