WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, includ- ing but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence.

The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.

FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:

1.Purchase Order number under which the product was PURCHASED,

2.Model and serial number of the product under warranty, and

3.Repair instructions and/or specific problems relative to the product.

FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:

1.Purchase Order number to cover the COST of the repair,

2.Model and serial number of the product, and

3.Repair instructions and/or specific problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering.

OMEGA is a registered trademark of OMEGA ENGINEERING, INC.

© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Page 30
Image 30
Omega Engineering RS-422/485 manual Warranty/Disclaimer

RS-422/485 specifications

Omega Engineering is a renowned leader in the field of measurement and control technologies, particularly in the realm of data communication for industrial automation. The RS-422 and RS-485 protocols are part of Omega's robust offering, designed to facilitate reliable and efficient data transmission over relatively long distances. These protocols are widely used in various applications ranging from industrial machinery to building automation systems.

One of the main features of RS-422 is its ability to support long-distance communication, allowing data to be transmitted up to 4,000 feet (approximately 1,200 meters) at speeds of up to 10 Mbps. This is achieved through the use of differential signaling, which provides improved noise immunity compared to single-ended signaling systems. RS-422 employs a single transmitter and multiple receivers, making it ideal for point-to-multipoint configurations.

On the other hand, RS-485 extends the capabilities of RS-422 by allowing multiple devices to be connected on the same bus. It supports up to 32 devices, which can be either transmitters or receivers, making it exceptionally versatile for networking applications. RS-485 can communicate effectively over distances up to 4,000 feet and at speeds of 10 Mbps as well. This makes it an attractive option for applications where several devices need to communicate with a central controller.

An essential characteristic of both protocols is their resilience to electromagnetic interference, which is often a concern in industrial environments. The differential signaling used in RS-422 and RS-485 reduces noise susceptibility, ensuring data integrity even in challenging conditions. Additionally, these protocols function effectively in half-duplex or full-duplex modes, providing flexibility based on application requirements.

Moreover, Omega Engineering’s implementations of RS-422 and RS-485 comply with established standards, ensuring compatibility with a wide range of devices. This interoperability is crucial for seamless integration into existing systems and enhancing overall productivity.

In summary, Omega Engineering's RS-422 and RS-485 technologies offer robust, reliable, and versatile solutions for data communication in industrial settings. With features such as long-distance communication, multiple device connections, and exceptional noise immunity, these protocols continue to serve as foundational technologies in various automation and control applications. As industries evolve, Omega Engineering remains committed to advancing these technologies to meet the growing demands of modern data communication.