Auto Calibration Instructions

For Models: RT1 T51 T52 T53 T54 T605 T805 CST3 CST4 CST5 T25 T35 1.2T 2.2T 3.2T 4.2T 5.2T 30516 T61 T62 T63

T64 T50 T70 CST3.5 CST4.5 PST6 PST8 T650 T805 30517 T10K 30518 T95 CST3.5x CST3.6 CST4.6 PST Pro PST6 PST8 T71 T72 T73 T74 1.3T 2.3T 5.3T T4 T6 DT680 LS925T RST5.6 RCT7.6 30519 30516 30517 WT751 WT951 610T 620T 700T 720T 730T 820T 830T 930T

F1

 

 

 

 

 

 

 

 

Distance / Laps

 

Time

 

 

 

Manual

Intervals

Rolling

Weight Loss

Hill Run

 

 

Hill Climb

Race

THR Zone

Custom 1

Custom 2

 

%

 

 

 

 

 

2

1 %

START

 

SELECT

 

STOP

1 mp

 

 

INCLINE

 

SPEED

 

 

F2

F3

Entering the Engineering Mode

1Turn the treadmill power to ON.

2Place the safety key in position on the console.

3Simultaneously press and hold (for about five seconds) the incline “+” (s) and speed “-” (t) buttons.(F1 & F2) For Model RT1: Simultaneously press and hold the 1 and 10 quick speed buttons for about three seconds. (F3)

4The console should beep three times and ENG0 (EN90) should be displayed. This indicates you are in the engineering menu.

Note: if ENG0 (EN90) is not displayed, but ENG (EN9) is displayed with another number at the end, you are still in the engineering menu. Use the “+” (s) or “-” (t) buttons to navigate to the correct menu. See following instructions.

Auto Calibration

WARNING

Do NOT stand on the running belt when calibrating. Use the guide rails instead.

After following the steps above you will have three steps left to complete the calibration process.

1Press the speed “+” (s) or “-“ (t) buttons until ENG2 (EN92) is displayed.

For Model RT1: Press the “Enter” button untill the display reads “Auto Set”.

2Press and hold the “Enter” button for about three seconds to select.

For Models 1.2T 2.2T 3.2T: Press and hold the “Select” button for about three seconds to select.

For Models T25 T35: Press and hold the “Start” button for about three seconds to select.

For Model RT1: Press the “Start” button to select Auto Set mode. (F3)

3Press the “Start” button to begin.

For Models 1.2T 2.2T 3.2T: Press the “Select” button to begin.

The running belt will begin moving and will automatically begin the auto-calibration sequence to properly set and store the speed values. Upon successful calibration there will be four beeps and it will automatically exit the Engineering Mode and will return to the original screen. The whole process will typically take about two minutes.

Auto Cal _rev1.5 08/17/07 JHP

Page 3
Image 3
Omega Speaker Systems Advance 300 manual Auto Calibration Instructions, Entering the Engineering Mode