Omega Speaker Systems Advance 300 manual Manual Calibration Instructions

Models: Advance 300

1 3
Download 3 pages 36.73 Kb
Page 1
Image 1

Manual Calibration Instructions

For Models: Omega Quantum Paragon Omega II Quantum II Paragon II Alpine Advance 200 Advance 300 Advance 400 Advance 500 TSC2 TSC3 TSC4 TSC5

IMPORTANT If the unit has a “Select” button and not the “Enter” button use the select to select the engineering mode on the screen.

F1

F2

Calories / Elevation

 

 

Speed / Pulse

 

 

 

 

 

 

 

10.46

Time

 

 

 

 

 

Speed

 

 

 

 

 

Elevation

 

 

 

 

 

 

INCLINE Distance / Laps

 

Time

SPEED

INCLINE

 

UP

 

 

 

DOWN

UP

 

 

 

 

 

 

INCLINE

 

 

 

 

 

 

START

 

 

 

 

 

SLOW

 

STOP

DOWN

 

 

 

 

HOLD TO PAUSE

START

STOP

SELECT

SELECT

 

UP

FAST

 

 

 

 

 

 

ELEVATION

SPEED

 

0.87 Distance

Pulse/Laps

Calories

SPEED

DOWN

SPEED

Entering Diagnostics Mode

1Turn the treadmill power to ON.

2Place the safety key in position on the console.

3Simultaneously press and hold the incline “+” (s) and speed “-” (t) buttons for about five seconds. (F1 & F2)

4The console will beep and display the software version in the one of the two following windows;

For Models Omega II Advance 200: in the Time window.

All other Models: in the Calories/Elevation window.

WARNING

Do NOT stand on the running belt when calibrating. Use the guide rails instead.

5Press Start. The running belt should begin moving.

6The Speed or Speed Pulse window will display the actual speed of the running belt. This should be 0.5mph.

7This should be 0.5mph (+ or - .05). If the speed is not within the proper start range, adjust the speed cube located on the lower control board. (F3)

Note: When adjusting the speed cube, turn the screw right to increase the speed and left to decrease the speed. Use small increments as the speed cube is sensitive and will respond to each change.

DO NOT PUSH DOWN HARD ON THE SCREW.

TRANSFORMER

F3

SPEED CUBE

Tip: Another way to verify the speed is set correctly: Count the running belt revolutions per minute. At 0.5mph the running belt should make 4 revolutions per minute for the Alpine and Advance 500 and 4.5 revolutions per minute for all other units.

IMPORTANT To exit the Engineering menu, press and hold “Stop” for three seconds.

Manual Calibration Pre Auto Cal _rev1.5 08/17/07

Page 1
Image 1
Omega Speaker Systems Advance 300 manual Manual Calibration Instructions, Entering Diagnostics Mode