Omega Vehicle Security CCT-80 Series manual Overview, Offset Adjust

Models: CCT-80 Series

1 14
Download 14 pages 63.71 Kb
Page 7
Image 7

SIGNAL INPUT, module ME

OVERVIEW

This module together with the "MP" input board, performs the signal conditioning (see Fig. 2). This module contains the trimmers and jumpers for the amplifier gain and the low level output (offset).

The signal input connections are made at Terminals 3, 4, 5 and 6.

FIG.7

 

1

 

P1

2

P2

 

 

B

A

C

Solder pads on solder side

P1 : Output zero adjustment.

P2 : Gain amplifier adjustment.

OFFSET ADJUST

Solder pad 1 if closed : Adjust the low range level of the output (Offset positive coarse).

Solder pad 2 if closed : Adjust the low range level of the output (Offset negative coarse).

Jumper A if closed : Adjust the low range level of the output (Offset negative fine).

AMPLIFIER GAIN

 

Jumper B if closed

: Gain at maximum level

Jumper C if closed

: Gain at medium level.

Jumpers B and C opened

: Gain at minimum level.

6

Page 7
Image 7
Omega Vehicle Security CCT-80 Series manual Overview, Offset Adjust