8.- WIRING

8.1.- POWER SUPPLY, RECOMMENDED WIRING

POWER SUPPLY

115 Vac (230 Vac Optional).

Power switch

FUSE and spare fuse.

8.2.- PROTECTION FUSES

The unit has a protection fuse located on the power supply socket.

If this fuse must be replaced or changed because the power supply is changed, use the time-lag fuse according to IEC 127/2 with the values indicated on the table.

8.3.- SENSOR CONNECTIONS FOR MODEL: MX.

Power

Fuse

Supply

value

 

 

230 Vac

0.2 A

115 Vac

0.4 A

 

 

D

Signal input C connector. B

A

PT-100

PT-100

3-wires connection.

2-wires connection.

Do not forget to link

 

 

terminal A

 

to

 

terminal C.

8.4.- SENSOR CONNECTIONS FOR MODELS: J1,J2,K1,K2,T1,T2,E1,E2,S1,S2,R1,R2 & L1.

D

Signal C input

connector. B

A

+

Thermocouple

_

Page : 8

Page 9
Image 9
Omega Vehicle Security LDP1XX-21 Power SUPPLY, Recommended Wiring, Protection Fuses, Sensor Connections for Model MX