Omega Vehicle Security warranty Specifications, Step One, LVCN700 Series Enclosure Top View

Models: LVCN700 Series

1 10
Download 10 pages 37.14 Kb
Page 2
Image 2
SPECIFICATIONS

SPECIFICATIONS

Step One

 

 

Range:

 

LVCN704: 2" to 4'

 

 

(5 cm to 1.2m)

 

 

LVCN709: 4" to 9.8'

 

 

(10 cm to 3m)

 

 

LVCN716: 4" to 16.4'

 

 

(10 cm to 5m)

 

 

LVCN126: 8" to 26.2'

 

 

(20 cm to 8m)

Repeatability:

0.25" (6 mm)

Adjustability:

Over entire range

Hysteresis:

LVCN704/709: 0.5" (1.2 cm)

 

 

(single set point)

 

 

LVCN716/726: 1" (2.5 cm)

 

 

(single set point)

Beam width:

LVCN704/709: 2" (5 cm) dia.

 

 

LVCN716/726: 3" (7.6 cm) dia.

Dead band:

LVCN704: 2" (5 cm)

 

 

LVCN709/716: 4" (10 cm)

 

 

LVCN726: 8" (20 cm)

LED indication:

Power, relay and echo status

Calibration:

Target, push button

Memory:

Non-volatile

Supply voltage:

AC: 95-250 VAC

 

 

DC: 12-28 VDC (Optional)

Consumption:

AC: 20 watts max.

 

 

DC: 100 mA @ 24 VDC (Optional)

Contact type:

(3) SPDT relays

Contact rating:

60 VA

Contact logic:

Single point: alarm

 

 

Two point: latching or

 

 

out of bounds alarms

 

 

Duplex or Alternation:

 

 

(Relays 1 and 2 only)

Contact fail-safety:

De-energizes during echo signal loss

Process temp.:

F: -4° to 140°

 

 

C: -20° to 60°

Temp. comp.:

Automatic

Electronics temp.:

F: -40° to 160°

 

 

C: -40° to 71°

Pressure:

30 psi (2 bar) @ 25° C., derated @

 

 

1.667 psi (.113 bar) per °C. above

 

 

25° C.

Enclosure rating:

NEMA 4X (IP65)

Enclosure vent:

Water tight membrane

Encl. material:

PC/ABS FR

Trans. material:

PVDF Kynar®

Process mount:

LVCN704/709: 1" NPT (1" G)

 

 

LVCN716/726: 2" NPT (2" G)

Mount. gasket:

Viton®

Conduit entrance:

Dual, 1/2" NPT

Classification:

General purpose

CE compliance:

EN 61326 EMC

 

 

[DC series only (DC powered)]

Handling Static-Sensitive Circuits/Devices: When han- dling the Ultrasonic switch, the technician should follow these guidelines to reduce any possible electrostatic charge build-up on the technicians body and the electronic part.

1.Always touch a known good ground source before handling the part. This should be repeated while handling the part and more frequently after sitting down from a standing position, sliding across the seat or walking a distance.

2.Avoid touching electrical terminals of the part unless making connections.

3.DO NOT open the unit cover until it is time to calibrate.

LVCN700 Series

Enclosure (Top View)

(104 mm)

(96 mm)

4.1"

3.8"

5.2" (133 mm)

LVCN704

LVCN709

Enclosure (Side View)

5.2" (133 mm)

mm)

2.4"(62 mm)

1.9"(49mm)

 

 

 

3.9" (100

1.2" mm)(32

0.75"

1" NPT (1" G)

 

 

 

 

(19 mm)

LU75

 

 

 

 

 

LVCN716

LVCN726

Enclosure (Side View)

5.2" (133 mm)

mm)

 

 

 

 

4.5" (114

3.0"(76 mm)

2.5"(63mm)

1.7"mm)(44

2" NPT

 

 

 

 

(2" G)

Temperature/Pressure Derating

(psi)

40

 

 

 

Unacceptable

 

 

 

 

 

 

30

 

 

 

 

Range

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

20

 

Acceptable

 

 

 

Operating

 

 

Range

 

 

 

 

10

 

 

 

 

 

 

00

 

 

 

 

 

 

 

-20

00

20

40

60

80

 

-40

Temperature (C¡)

Page 2
Image 2
Omega Vehicle Security Specifications, Step One, LVCN700 Series Enclosure Top View, LVCN704 LVCN709 Enclosure Side View