424

Note 1. The area specified under “Name” must be in four characters. Fill any gaps

with spaces to make a total of four characters.

2. Words 253 to 255 cannot be set when the CIO Area is specified.

11-3-26MULTIPLE FORCED SET/RESET –– FK

Force sets, force resets, or cancels the status of the bits in one word in the IR,

SR, LR, HR, AR, or TC area.

Command Format
:
@FK
x 100
x 101x 103x 102x 101x 100
OP1 OP2 OP3 OP4
15 14 13 12 11 10 1 0
Node no. Header
code Name Word
address
Forced set/reset/cancel data
Bit
x 160x 160x 160
x 160x 160x 160x 160
x 160
TerminatorFCS
Response Format
@FK
x 100
x 101x 161x 160:
Node no. Header
code TerminatorFCSEnd code

Parameters Name, Word address (Command)

In “Name”, specify the area (i.e., IR, SR, LR, HR, AR, or TC) that is to be forced

set or reset. Specify the name in four characters. In “Word address”, specify the

address of the word that is to be forced set or reset.

Name Classification Word address setting Bit
OP1 OP2 OP3 OP4
g
range
C I O (S) IR or SR 0000 to 0511 00 to 15 (decimal)
L R (S) (S) LR 0000 to 0063
()
H R (S) (S) HR 0000 to 0099
A R (S) (S) AR 0000 to 0027
T I M (S) Completion Flag (timer) 0000 to 0511 Always 00.
T I M H Completion Flag (high-speed timer)
y
C N T (S) Completion Flag (counter)
C N T R Completion Flag (reversible counter)
T T I M Completion Flag (totalizing timer)
(S): Space

Note Words 253 to 255 cannot be set when the CIO Area is specified.

Host Link Commands Section 11-3