427

Parameters Program (Response)
The program is read from the entire program area.
Note To stop this operation in progress, execute the ABORT (XZ) command.
11-3-31PROGRAM WRITE –– WP
Writes to the PC user’s program area the machine language (object code) pro-
gram transmitted from the host computer. The contents are written as a block,
from the beginning.
Command Format
@WP
x 100
x 101x 161x 160:
Node no. Header
code 1 byte
Program (Up to maximum memory size)
TerminatorFCS
Response Format
@WP
x 100
x 101x 161x 160:
Node no. Header
code End code TerminatorFCS
Parameters Program ((Command)
Program data up to the maximum memory size.
11-3-32I/O TABLE GENERATE –– MI
Corrects the registered I/O table to match the actual I/O table.
Command Format
@MI
x 100
x 101:
Node no. Header
code TerminatorFCS
Response Format
@MI
x 100
x 101x 161x 160:
Node no. Header
code End code TerminatorFCS
11-3-33COMPOUND COMMAND –– QQ
Registers at the PC all of the bits, words, and timers/counters that are to be read,
and reads the status of all of them as a batch.

Registering Read Information

Register the information on all of the bits, words, and timers/counters that are to
be read.