Ordering Information

Special I/O Units

Isolated-type Thermocouple Input Units

Unit

Product

I/O

Signal

Signal

Conver-

Accuracy at

External

No. of

Current

Model

Standards

classi-

name

points

range

range

sion speed

ambient

connec-

unit

consump-

 

 

fica-

 

 

 

selec-

 

(resolution)

temperature

tion

num-

tion (A)

 

 

tion

 

 

 

tion

 

 

of 25°C)

 

bers

 

 

 

 

 

 

 

 

 

 

 

 

 

allo-

5 V

24 V

 

 

 

 

 

 

 

 

 

 

 

cated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ1

Process

2 in-

Set

Thermocou-

Conversion

Standard

Remov-

1

0.18

0.06

CJ1W-

UC1, CE

Spe-

Input

puts

sepa-

ple: B, E, J,

speed:

accuracy:

able termi-

 

 

(See

PTS15

 

cial I/O

Units

 

rately

K, L, N, R, S,

10 ms/

±0.05% of F.S.

nal block

 

 

note

 

 

Units

(Isolated-

 

for

T, U,

2 inputs,

(See note 1.)

 

 

 

2.)

 

 

 

type

 

 

 

 

 

 

 

 

each

WRe5-26,

Resolution:

 

 

 

 

 

 

 

 

Thermo-

 

 

 

 

 

 

 

 

 

 

input

PLII

1/64,000

 

 

 

 

 

 

 

 

couple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

DC voltage:

 

 

 

 

 

 

 

 

 

Units)

 

 

±100 mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 in-

Com-

Thermocou-

Conversion

Accuracy:

 

 

0.25

---

CJ1W-

 

 

 

 

puts

mon

ple: R, S, K,

speed:

±0.3% of PV

 

 

 

 

PTS51

 

 

 

 

 

inputs

J, T, L, B

250 ms/

or ±1°C,

 

 

 

 

 

 

 

 

 

 

 

 

4 inputs

whichever is

 

 

 

 

 

 

 

 

 

 

 

 

 

larger, ±1 digit

 

 

 

 

 

 

 

 

 

 

 

 

 

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

(See note 3.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: 1. The accuracy depends on the sensors used and the measurement temperatures. For details, refer to the user’s manual.

2.This is for an external power supply, and not for internal current consumption.

3.L and 100°C or less for K and T are ±2°C±1 digit max., and 200°C or less for R and S is ±3°C±1 digit max. No accuracy is specified for 400°C or less for B.

Isolated-type Resistance Thermometer Input Units

Unit

Product

I/O

Signal

Signal range

Conver-

Accuracy at

Exter-

No. of

Current

Model

Standards

classi-

name

points

range

 

sion speed

ambient

nal

unit

consump-

 

 

fica-

 

 

 

selec-

 

(resolution)

temperature

con-

num-

tion (A)

 

 

tion

 

 

 

tion

 

 

of 25°C)

nec-

bers

 

 

 

 

 

 

 

 

 

 

 

 

tion

allo-

5 V

24 V

 

 

 

 

 

 

 

 

 

 

 

cated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ1

Process

2 in-

Set

Platinum resis-

Conversion

Accuracy:

Remov-

1

0.18

0.07

CJ1W-

UC1, CE

Spe-

Input

puts

sepa-

tance thermom-

speed:

±0.05% of F.S.

able

 

 

(See

PTS16

 

cial I/O

Units

 

rately

eter: Pt100,

10 ms/

or ±0.1°C,

termi-

 

 

note.)

 

 

Units

(Isolated-

 

for

JPt100, Pt50,

2 inputs,

whichever is

nal

 

 

 

 

 

 

type

 

 

 

 

 

 

 

 

each in-

Ni508.4

Resolution:

larger.

block

 

 

 

 

 

 

Resis-

 

 

 

 

 

 

 

 

put

 

1/64,000

 

 

 

 

 

 

 

 

tance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ther-

 

4 in-

Com-

Platinum resis-

Conversion

Accuracy:

 

 

0.25

---

CJ1W-

 

 

mometer

 

 

 

 

puts

mon

tance thermom-

speed:

±0.3% of PV

 

 

 

 

PTS52

 

 

Input

 

 

 

 

 

 

 

inputs

eter: Pt100,

250 ms/

or ±0.8°C,

 

 

 

 

 

 

 

Units)

 

 

 

 

 

 

 

 

 

 

JPt100

4 inputs

whichever is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

larger, ±1 digit

 

 

 

 

 

 

 

 

 

 

 

 

 

max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: This is for an external power supply, and not for internal current consumption.

Isolated-type DC Input Unit

Unit

Product

I/O

Signal range

Conver-

Accuracy at

External

No. of

Current

Model

Standards

classi-

name

points

 

sion speed

ambient

connec-

unit

consump-

 

 

fica-

 

 

 

(resolution)

temperature

tion

num-

tion (A)

 

 

tion

 

 

 

 

of 25°C)

 

bers

 

 

 

 

 

 

 

 

 

5 V

24 V

 

 

 

 

 

 

 

 

 

allo-

 

 

 

 

 

 

 

 

 

cated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ1

Isolated-

2 in-

DC voltage:

Conversion

Accuracy:

Remov-

1

0.18

0.09

CJ1W-

UC1, CE

Special

type DC

puts

0 to 1.25 V,

speed:

±0.05% of F.S.

able

 

 

(See

PDC15

 

I/O

Input

 

1.25 to 1.25 V,

10 ms/

 

terminal

 

 

note.)

 

 

Unit

Unit

 

0 to 5 V, 1 to 5 V,

2 inputs,

 

block

 

 

 

 

 

 

 

 

5 to 5 V,

Resolution:

 

 

 

 

 

 

 

 

 

 

0 to 10 V,

1/64,000

 

 

 

 

 

 

 

 

 

 

10 to 10V,

 

 

 

 

 

 

 

 

 

 

 

±10-V select-

 

 

 

 

 

 

 

 

 

 

 

able

 

 

 

 

 

 

 

 

DC current: 0 to 20 mA, 4 to 20 mA

Note: This is for an external power supply, and not for internal current consumption.