3-1 Installation of Antenna

3-1

3-1 Installation of Antenna

3-1-1 Installation Environment

Installation Location

It is assumed that this product is to be used indoors, or outdoors if there is a roof.

Do not install the Antenna in the following locations.

Place exposed to direct sunlight.

The ambient temperature is not within a range between 10°C and 55°C or locations with radical temperature changes resulting in condensation.

The humidity is not within a range between 35% and 85%.

There is corrosive gas, flammable gas, dust, salt, or metal powder.

The Antenna will be subjected to direct vibration or shock.

Oil, or chemical will be sprayed onto the Antenna.

Vicinity of noise source.

Peripheral environment

1) Influence of peripheral electronic devices

Any peripheral electronic devices present may reduce communication range. Ambient noise can cause the communications range of the Antenna to drop.

Ambient noise can be reduced by taking the following countermeasures.

Power Lines and High-tension Lines.

Do not wire the Antenna cable along with high–tension lines or power lines. Keep the Antenna cable as far away as possible from them.

Inverters, Motors, and Other Driving Mechanisms.

Be sure to ground the frames of driving mechanisms and keep them as far away as possible from the Antenna.

Switching Power Supplies.

Be sure to ground switching power supplies and keep them as far away as possible from the Antenna.

2)Influence of peripheral metals

Large metal objects around the Antenna may reduce communication distance; therefore, place such metal objects at least the following distances away from the Antenna:

Distance between back metal of Antenna and back surface of Antenna: 50cm or more.

Distance between side metal of Antenna and side of Antenna: 30cm or more.

! Caution Before installation, perform sufficient tests following the above points.

3-2

Page 17
Image 17
Omron V720-HS04 user manual Installation of Antenna, Installation Environment