XI. Wiring Diagram for Magnetic Starter (220v, 1 ** )*

Always use a licensed, professional electrician.

Dedicated Receptacle Fed from 2 Pole Dedicated Circuit Breaker,

6-20R

I

Motor

O

Baldor 2hp

 

Catalog

 

#VL3515T

 

6-20P

Magnetic Starter -

Mount Close to Collector

6’ Long Type SJT

14 AWG Power Cord

*Note: Motor Starter supplied with system is for 220v only.

Open access cover on the Overload.

Note: Overload must be set or nuisance tripping may occur.

Set the overload amperage dial for the SFA* amperage of your motor. The SFA* value can be found below: SFA = 12.1

(FLA 11.5)

Note: This Dust Collector is pre-wired at the factory and need only be plugged into a NEMA 6020R dedicated electrical receptacle. 3hp single phase only.

Optional Remote Controller diagram pg. 19

*SFA - Service Factor Amperage

*FLA - Full Load Amperage

*Starter will not operate at any other voltages.

**Starter is shown configured for 1O but can also be used for 2hp, 3O motors.

12

2HP Super Dust Gorilla Owner’s Manual c O.A.S. 2007