III. General Specifications & Fan Performance Curves
2.0 hp
Height without | Cyclone | Inlet | Weight without | TEFC* | |
Dust Bin | Diameter | Diameter | Dust Bin | Motors | |
|
|
| Approx. Wt. | Class F | |
63” | 21” | 7” | 122 lbs. | 115/230v | |
23/11.5 amps | |||||
|
|
| w/o drum or filter | ||
|
|
| 1.15 Service Factor | ||
|
|
|
| ||
|
|
|
|
|
-Sleeve kit adds 7” (4” is minimum)
-35 gal. bin is 22” dia. x 22.5” h / 55 gal. bin is 22” dia. x 35.5” h
-Several Filter Options Available- Galvanized steel construction
-The collector can be hung on the wall, from the ceiling, or free standing support using
the 10 ga. angle iron ring at the top of the cone. (See assembly instructions)
2hp Super Dust Gorilla System
1422 CFM @ 2.3” SP w/c w/o filter
Industrial Baldor TEFC 2hp motor*
115/230v - 23/11.5 amps / 1.15 Service Factor
Full 16 gauge galvanized cyclone & 11 ga. fan housing 7” dia. inlet / 8” rectangular outlet
14.25” dia. x 4” wide cast aluminum fan wheel
back inclined
Sound 78 - 79dB @ 10’ with
95 Sq. Ft. Filter Media /
*Note: Motor Starter supplied with system is for 220v only.
Static pressure and volume together determine a fan’s performance. Several factors, such as layout of ductwork and diameter of openings, can affect a fan’s performance.
Static Pressure at Cyclone Inlet
11
10
9
8
7
6
5
4
3
2
0
2hp Super Dust Gorilla CFM vs. SP Curve*
10.65
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| 9.4 |
|
| 8.25 |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6.3 |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1422 cfm @ |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2.3” SP w/c |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| w/o filter. |
| |||
|
|
|
|
| 4.3 |
|
|
|
| Vented outside. |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| - Without Filter |
|
|
|
|
| 1349 cfm @ 2.3” |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| SP w/c w/ filter. | 3 | 2.3 |
| |||||||||
|
| - With Filter |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
| FCS133900 |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Fan curves vary slightly with different filter packages.
0 | 200 | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | |
|
|
|
| CFM |
|
|
|
|
|
|
|
|
|
|
|
| 4 | ||
|
|
|
|
|
|
|
|
|
|
2HP Super Dust Gorilla Owner’s Manual c O.A.S. 2007