Manuals
/
Brands
/
Computer Equipment
/
Scanner
/
Opticon
/
Computer Equipment
/
Scanner
Opticon
LPN 1736
to create a window, Cut and Remove this section, Scanning Template for Programming
1
8
149
149
Download
149 pages, 558.29 Kb
Manual No.
25-ULPNMU01-01
LPN1736
Omni-Directional
Laser Scanner
Scanning Template for Programming
Cut and Remove this section
to create a window
Page 8
Contents
LPN
Omni-DirectionalLaser Scanner
25-ULPNMU01-02
Contents
Chapter 5 Programming Symbology Options
Chapter 6 Universal Programming Options
Appendices
NOTICE
Getting Started
Parts of the Scanner
Reading Window
Trigger Button
Good Read Indicator
Buzzer/Beeper
Opticon Customer Service and Support
Programming Bar Codes
Scanning Template for Programming
Cut and Remove this section
to create a window
Keyboard Wedge Interface
Reset All Defaults
Keyboard Type Selection
XT Keyboard Wedge UA
PS2 Keyboard Wedge UC
Page
No Delay (LA)
Delay = 1 (LB)
Delay = 2 (LC)
Delay = 3 (LD)
Delay = 4 (LE)
Delay = 5 (LF)
Delay = 6 (LG)
Delay = 7 (LH)
Delay = 8 (LI)
Delay = 9 (LJ)
Delay = 10 (LK)
RS232 Interface
Reset All Defaults – RS232
No Handshaking (P0)
ACK / NAK (P3)
Xon / Xoff (ZG)
Unlimited (I0)
Flow Control = 100ms (I1)
Flow Control = 200ms
Flow Control = 400ms (I3)
Baud Rate = 19200 (K7)
Baud Rate = 9600 (K6)
Baud Rate = 4800 (K5)
Baud Rate = 2400 (K4)
Baud Rate = 1200 (K3)
Baud Rate = 600 (K2)
7 Data Bits (L0)
8 Data Bits (L1)
1 Stop Bit (L5)
2 Stop Bits (L6)
Even Parity (L3)
Odd Parity (L4)
Mark No Parity (L2)
USB Interface
Programming the Scanner
What if you make a mistake
Reset All Defaults
Programming Symbology Options
Enable All Symbologies (A0)
Enable Only All UPC/EAN (J0)
Enable UPC Only (J1)
Enable UPC+2 only (J2)
Enable UPC+5 Only (J3)
Enable EAN Only (J4)
Enable EAN+2 only (J5)
Enable EAN+5 Only (J6)
Enable Code 39 Only (A2)
Enable only Codabar (A3)
Enable Only Code 128 (A6)
Enable Code 93 Only (A5)
Enable only MSI Plessey (A7)
Enable Only Industrial 2of 5 (J7)
Enable Only Interleaved 2of 5 (J8)
Enable only IATA (A4)
Add UPC (R1)
Add UPC+2 (R2)
Add UPC+5 (R3)
Add EAN (R4)
Add EAN+2 (R5)
Add EAN+5 (R6)
Add Code 39 (B2)
Add Codabar (B3)
Add Industrial 2of5 (R7)
Add Interleaved 2of 5 (R8)
Add Code 128 (B6)
Add Code 93 (B5)
Add IATA (B4)
Add MSI / Plessey (B7)
UPC-ALeading zero Transmit Check Digit (E2)
UPC-ANo leading zero
Do not transmit Check Digit
UPC-ALeading zero Not transmit Check Digit
UPC-Eno leading zero Transmit Check Digit (E7)
UPC-Eno leading zero
Not transmit Check Digit
UPC-Eleading zero Transmit Check Digit (E6)
UPC-ELeading zero Not transmit Check Digit
UPC-ETransmit as is
UPC-ETransmit as UPC-A(6P)
EAN-13Transmit Check Digit (6K)
EAN-13Not transmit Check Digit
EAN-8Transmit Check Digit (6I)
EAN-8Not transmit Check Digit (6H)
Enable ISBN
(IA)
Disable ISBN (IB)
Enable ISSN (HO)
Disable ISSN
(HN)
Standard Code
Full ASCII Code
Transmit Start/Stop Characters (D0)
Do not transmit Start/Stop Character (D1)
Do not transmit Check Digit (D8)
Transmit Check Digit (D9)
Calculate Check Digit (C0)
Do not calculate Check Digit (C1)
Do not transmit Start/Stop Characters (F0)
Transmit Start/Stop as
ABCD/tn*E
abcd/tn*e
ABCD/ABCD
abcd/abcd
Do not calculate Check Digit (G0)
Calculate Check Digit
Transmit Check Digit (E0)
Do not transmit Check Digit (E1)
Minimum data: 1 Character
(GE)
Minimum data: 3 Characters (GF)
Minimum data: 5 Characters (GI)
Not Check Digit
Calculate Check Digit 1
Modulo
Calculate Check Digit 2
Modulo 10/Modulo 10 (4C)
Modulo 10/Modulo 11 (4D)
Do not transmit Check Digit (4G)
Transmit Check Digit 1 (4E)
Transmit Check Digit 1 & 2 (4F)
Do not calculate Check Digit (4H)
Check S/N only (4I)
Check CPN, S/N (4J)
Check CPN,Airline and S/N (4K)
Transmit Check Digit (4L)
Do not transmit Check Digit 1 (4M)
Universal Programming Options
No Redundacy (X0)
Read 2 times
Read 3 times (X2)
Read 4 times (X3)
Single Read (S0)
Multiple Read (S1)
Continuous Read (S2)
Disable Beeper (W0)
Single Tone Beeper (W1)
High - Low Beeper (W2)
Low - High Beeper (W3)
Beeper Duration: 50ms (W7)
Beeper Duration: 100ms (W4)
Beeper Duration: 400ms (W6)
Loudness: Maximum (T0)
Loudness: Loud (T1)
Loudness: Normal (T2)
Loudness: Minimum
Beeper before transmission (VY)
Beeper after transmission (VZ)
DEFAULT
Clear All Prefixes (MG)
Add Prefix to All Symbologies (RY)
Add Prefix to UPC-A(N1)
Add Prefix to UPC-Aplus all add-ons(M0)
Add Prefix to UPC-E(N2)
Add Prefix to UPC-Eplus all Add-Ons(M1)
Add Prefix to EAN-13(N3)
Add Prefix to EAN-13plus Add-Ons(M2)
Add Prefix to EAN-8
Add Prefix to EAN-8plus Add-Ons(M3)
Add Prefix to Code 39 (M4)
Add Prefix Codabar (M5)
Add Prefix to Industrial 2of5 (M6)
Add Prefix to Interleaved 2of5 (M7)
Add Prefix to IATA (I8)
Add Prefix to Code 93 (M8)
Add Prefix to Code 128 (M9)
Add Prefix to MSI/Plessey (N0)
Add Prefix to Telepen (L8)
Clear All Suffixes (PR)
Add Suffix to All Symbologies (RZ)
Add Sufffix to UPC-A(N6)
Add Suffix to UPC-Aplus all add-ons(O0)
Add Suffix to UPC-E(N7)
Add Suffix to UPC-Eplus all Add-Ons(O1)
Add Suffix to EAN-13(N8)
Add Suffix to EAN-13plus Add-Ons(O2)
Add Suffix to EAN-8(N9)
Add Suffix to EAN-8plus Add-Ons(O3)
Add Suffix to Code 39 (O4)
Add Suffix to Codabar (O5)
Add Suffix to Industrial 2of5 (O6)
Add Suffix to Interleaved 2of5 (O7)
Add Suffix to IATA (I9)
Add Suffix to Code 93 (O8)
Add Suffix to Code 128 (O9)
Add Suffix to MSI/Plessey (N5)
Add Suffix to Telepen (L9)
F1 Key
F2 Key
F3 Key
F4 Key
F5 Key
F6 Key
F7 Key
F8 Key
F9 Key
F10 Key
F11 Key
F12 Key
Backspace (9X)
TAB (7H)
Carriage Return (7I)
Enter (numeric pad) (7Q)
Enter make (alpha pad) (7R)
Enter make and break (alpha pad) (7S)
ESC (7J)
Arrow down (7K)
Arrow up (7L)
Arrow right (7M)
Arrow left (7N)
<DEL
<INSERT
(VQ)
<HOME
(VR)
<END
Page up (7O)
Page down (7P)
Left <Control> (7W)
Left <Alt> (7Y)
Right <Shift> (7V)
Right <Control> (7X)
Right <Alt> (7Z)
CAPSLOCK (9S)
Space bar (5A)
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
Page
^@ (NULL) (9G)
^A(SOH)
^B(STX)
^C(ETX)
^D(EOT)
^E(ENQ)
^F(ACK)
^G(BEL)
^H(BS)
^I(HT)
^J(LF)
^K(VT)
^L(FF)
^M(CRF)
^N(SO)
^O(SI)
^P(DLE)
^Q(DC1)
^R(DC2)
^S(DC3)
^T(DC4)
^U(NAK)
^V(SYN)
^W(ETB)
^X(CAN)
^Y(EM)
^Z(SUB)
^[(ESC)
^\(FS)
^](GS)
^^(RS)
^_ (US) (9E)
DEL (ASCII 127) (9F)
Code Identification ($2)
Code Length ($3)
[BBB
Enable Trigger (S8)
Readtime: Indefinite (YM)
Trigger Sensitivity = Avg (+I)
Disable Motor When Idle (4Z)
Set Auto Shut Off Time (BBB)
Direct Input: 3 (Q3)
Direct Input: 6 (Q6)
Direct Input: 0 (Q0)
Auto Trigger = Avg. Setting (+I)
Auto Trigger = Bright/Dark (+H)
Auto Sensor = Dark/Bright (+G)
Motor at ½ Speed When Idle (BBA)
Page
Page
Page
Default (U2)
Transmit UPC E as UPC A (6P)
1200 Baud
Add Prefix for UPC A (N1)
Prefix = A
Add Prefix for EAN 8 (N4)
Set Prefix for EAN 13
Prefix for EAN 13 = A (0A)
LPN1736 Manual Update- September 13