25. Scanner Timeout (Trigger Enabled Mode only)
These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period
after the trigger pulse is received. The Time-out period is the same whether the scanner is operating in
Single, Multiple or Continuous Read mode.
Computer
Command
Function
/Description
Bar Code
Command
(Z7) START/END
Programming Menu -[8-
Y0
Trigger remains ON
as long as trigger is pulled
(hardware trigger only) -Z1-
Y1 1 Second after triggering -Z2-
Y2 2 Seconds after triggering -Z3- %
Y3 3 Seconds after triggering -Z!-
Y4 4 Seconds after triggering -Z5-
Y5 6 Seconds after triggering -Z6-
Y6 8 Seconds after triggering -Z7-
Y7 10 Seconds after triggering -Z8-