Oracom MAX 695 dimensions Drain Valve, Repair, Replacement

Models: MAX 695

1 28
Download 28 pages 49.8 Kb
Page 18
Image 18

Drain Valve

1.

Relieve pressure; page 3.

2.Turn handle (54) to closed position. Drive out pin (53). Remove handle.

3.Remove base (52).

4.Unscrew drain valve assembly (51). gasket (55) and seat (56) will stay in valve.

55

56 2

51

Repair

1.Unscrew spring retainer from valve body. Remove spring, washers and stem/ball. Clean any debris from ball or seat area.

2.If replacing gasket (55) or seat (56), pry out gas- ket.

NOTE: Whenever gasket (55) is removed, replace it with a new one.

3.Place seat (56) in drain valve assembly (51) so lapped side is toward ball. Apply a small amount of grease to new gasket (55) and install it in drain valve assembly.

1

1 Torque into pump manifold to

52 3

53

NOTE: The gasket will protrude from the end of the valve until the valve is tightened into pump, which correctly seats the gasket.

Replacement

1. Apply a small amount of thread sealant (110110)

onto drain valve assembly (51) threads. Tighten

185 in-lb (21 N￿m)

2 Apply thread sealant

54 4

the valve into the pump manifold (229) to 185 in-lb

(21 N￿m).

3Apply grease to face of base

4Handle shown in closed position

Fig. 17

7839A

 

2.

Lightly grease face of base (52) and install base.

 

Turn stem so pin hole is vertical.

3.

Securely install handle (54) and drive pin (53).

18 309067

Page 18
Image 18
Oracom MAX 695 dimensions Drain Valve, Repair, Replacement