Orbit Manufacturing ORBIT-6 RP-206 Enter, Installer, Programming, Mode Access Press 0, 8, ARM

Models: ORBIT-6 RP-206

1 37
Download 37 pages 14.26 Kb
Page 13
Image 13

 

Operation

Action

Comments

 

 

1

Enter the

enter the factory default

a long beep will sound, confirming

 

Installer

Installer Code (0-2-0-6);

successful entry into Installer

 

 

Programming

followed by #

Programming

 

 

 

mode

 

 

 

 

 

2

Access the

press [0], [8], [ARM]

no confirming beep will sound

 

 

current Installer

 

 

 

 

 

 

Code

 

 

 

 

 

 

(stored in location

 

 

 

 

 

 

“08”)

 

 

 

 

 

3

Enter a unique

enter [3], [0], [5], [7]

no confirming beep will sound

 

 

Installer Code

 

 

 

 

 

 

(for this tutorial,

 

 

 

 

 

 

we’ll use 3-0-5-7)

 

 

 

 

 

4

Store the data

press [#]

a long beep will sound confirming that

 

you have entered

 

data has been properly stored

 

 

 

 

if a wrong number of digits entered

 

 

 

three (error) beeps will sound after

 

 

 

pressing #

 

 

 

5

Check the data

the first digit of the stored

press

displayed

zone

value

 

stored in Location

data will appear

keys

 

LEDs

 

 

“08”

observe the Zone LEDs

 

 

lit

 

 

 

press [STAY] [STAY] to

none

1st digit

2, 1

3

 

 

advance to the next digit

 

 

 

 

 

 

once all four digits have

STAY

2nd digit

none

0

 

 

been displayed, attempts to

 

 

STAY

 

 

 

 

 

view an additional digit will

 

 

 

 

 

 

STAY

3rd digit

 

 

 

 

result in three (error) beeps

3,1

5

 

 

if desired, press [STAY]

STAY

 

 

 

 

 

STAY

 

 

 

 

 

and [ARM] to move

4th digit

3,2,1

7

 

 

backwards

STAY

 

 

 

 

 

 

 

6

Go to another

press the desired two-digit

press [ARM] alone to go to the next

 

location of your

location and [ARM]

sequential location

 

 

 

choice

 

 

 

 

 

7

Exit

enter your Installer Code

a long beep will confirm your actions

 

programming

and press [ARM]

 

 

 

 

Installer Manual

13

Page 13
Image 13