Location: 18 Zone 5: (2nd Digit): Sound
Default: External Sounder (Pulses)
For fire zone the recommended (default) zone sound is “External sounder pulsed” However it is possible to change the zone sound and type to any of the ones provided in the previous list.
Location: 19 Zone 6: Tamper Zone
Zone 6 is reserved as a Tamper Zone. This zone can be programmed to any zone type (except Fire) including Tamper. If the zone was programmed as Tamper, in violation, a Tamper Code report will be sent and the Tamper LED on the keypad (marked as 6/Tmp) will light up.
UTILITY OUTPUTS: LOCATIONS 22-25
The
Note: When activated the utility output is switched to the Negative Polarity.
The “UO” can be also used to reset a “latched” Smoke Detector(s). In that case the 12V power to the smoke detector will be supplied via the UO (see Figures 1A and 1B). The UO should be defined as AUX switch.
If the Utility Output Expansion Module is being used, the same information in Location 22 is applicable for the programming of UO2 (Location 23), UO3 (Location 24), and/or UO4 (Location 25). It is not necessary to program all of the available “UOs”, unless they’re used. Note that when the Utility Output Expansion Module is employed, the original Utility Output on the Main Board (the UO/ECL terminal) is no longer available.
Important: In order to use the Utility Output Expansion you have to define the module in Location 30.
22
If more than one “UO” output is necessary, a Utility Output Expansion Module is available. Its four “UOs” (U01, UO2, UO3, and UO4) replace the
Because of the “UO’s” modest 70 mA current capability, it will be necessary to use an “intermediate”