Location: 28
CS Protocols:
When selecting a contact ID & SIA format, all the reporting codes will be automatically applied to the locations of the reporting codes.
To change a code, enter a new code (according to the type of event – see page 30) to the corresponding location.
When selecting the Pulsed Protocol the default for all the reported codes will be “00” and any other code should be entered manually
To remove a particular reporting code from any of the 3 Protocols enter “00” into the corresponding location.
Important: Choose the code format only after defining the zone parameters. Changing a zone type after selecting the code format WILL NOT change the zone’s reporting code and a faulty report will be sent to the central station.
Digit | Format Name | Interdigit Time | Data Frequency |
00 | Pulsed Protocol |
|
|
01 | Contact ID | NA | NA |
02 | SIA | 390 ms | 1800 Hz |
**03 | Ademco 4/2 Express |
|
|
(Ver. 1.3) |
|
|
Upload/Download Rings: Location 29
Location 29 sets the number of rings that the
Location: 29
Number of Rings
Default: 12
Choose a number of rings greater than that which the customer will normally wait to answer
an incoming call enter two digits; (between | Number | |
Note: if an Answering Machine is in use and so programmed | of Rings | |
(see Location 26 / 2nd Digit), entries made in this location will be ignored |
|
|
SYSTEM CONTROLS: LOCATION 30
Location 30 allows you to specify some additional parameters, which determine how the
∙First digit: determine the number (or letter) corresponding to the choices involving Quick Arm / Quick Bypass / UO Extender / Loudspeaker /
∙Second digit: determine the number (or letter) corresponding to the use of Silent Panic / Bell Squawk on Arming / 3 Minute Bypass
Comments on System Controls (Location 30: 1st Digit)
Quick Arm | Quick Bypass | UO Extender | |
|
|
|
|
Quick Arm | Eliminates the | select UO Extender | select Loudspeaker if the |
eliminates the | need to enter a | if the Utility Output | external sounder(s) is NOT |
need for entering | User Code when | Expansion Module is | equipped with a |
a User Code when | bypassing a zone. | installed | driver; doing so causes the |
arming to the STAY |
|
| |
or AWAY modes. |
|
| oscillating frequency for the |
simply pressing |
|
| device, select Bell/Siren if the |
[STAY] or [ARM] will |
|
| external sounder(s) is a bell or |
arm the system to |
|
| a buzzer or equipped with a |
the respective mode |
|
|