on the worm gear shaft. Then tighten the screw.
12.To place the finder scope in the finder scope bracket |
(Figure 3), first unthread the two black nylon thumbscrews |
until the screw ends are flush with the inside diameter of |
the bracket. Place the |
the bracket over the body of the finder scope until it seats |
into the groove on the middle of the finder scope. Slide the |
eyepiece end (narrow end) of the finder scope into the end |
of the bracket’s cylinder that does not have the alignment |
thumbscrews while pulling the chrome, |
sioner on the bracket with your fingers. Push the finder |
scope through the bracket until the |
the front opening of the bracket cylinder. Now, release the |
tensioner and tighten the two black nylon thumbscrews a |
couple of turns each to secure the finder scope in place. |
13.Insert the base of the finder scope bracket into the dove- |
tail slot on the top of the focuser. Lock the bracket into |
position by tightening the knurled thumbscrew on the |
dovetail slot. |
14.Remove the cover cap on the end of the focuser. Insert the |
chrome barrel of the star diagonal into the focuser and |
secure with the thumbscrew on the drawtube. |
Objective |
| Black nylon | ||||||||||
lens cell |
|
|
|
|
|
|
|
|
|
| alignment | |
|
|
| ||||||||||
Lock ring |
|
|
|
|
|
|
|
| thumbscrews | |||
|
|
|
|
|
|
|
|
| Eyepiece | |||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||||
Dovetail base |
|
|
|
|
|
|
Figure 3. The 6x30 finder scope and bracket.
15.Then insert an eyepiece into the star diagonal and secure |
it in place with the thumbscrews on the diagonal. (Always |
loosen the thumbscrews before rotating or removing the |
diagonal or an eyepiece.) |
16.Install the polar axis finder scope into its housing inside |
the R.A. axis of the equatorial mount (Figure 4). First |
loosen the three thumbscrews on the housing, which is |
located at the rear of the R.A. axis. Insert the front end of |
the polar finder (the end without the eyeguard) into the |
housing so only about 1" of the polar finder extends from |
the back of the housing. Do this slowly and with a twisting |
motion to prevent the internal |
unseated. If it does become unseated, you can remove |
Date circle
Ring with engraved time meridian indi- cator mark
Polar scope alignment thumbscrew (3)
Pointer
R.A. setting circle
Meridian offset scale
Polar scope housing
Polar axis finder scope
the entire housing from the mount to locate the |
reseat it. This is done by rotating the entire housing coun- |
terclockwise. Once the polar axis finder scope is in the |
housing, tighten the three thumbscrews. These thumb- |
screws will be used later to align the finder with the |
mount’s R.A. axis. |
17.Remove the objective lens dust cover. |
The AstroView 120ST is now assembled and should appear as pictured in Figure 1.
Figure 4. The polar axis finder scope installed in the right ascension (R.A.) axis of the mount.
5