Welcome to the OutBack Power Systems
The
OutBack Power Systems does everything possible to assure the components you purchase will func- tion properly and safely when installed as instructed according to local and national electrical codes (NEC). Please read all of the following instructions and the instructions that come with any other OutBack components that make up your power system.
The FW-X240 Auto Transformer Specifications:
•120 volt/25 amp primary and secondary side
•120 or 240 VAC 60 Hz systems only
•Allows powering 240 volt items ( e.g., a deep well pump) with a single 120 volt AC source
•
Two identical windings:
•Winding one is between leads #1 and #2
•Winding two is between leads #3 and #4
•The start for each winding are on lead #1 and on lead #3
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Please read all instructions and cautionary markings on the
To reduce risk of electric shock:
•Disconnect all DC and AC power sources before attempting any maintenance or repair.
•The input side of the AC and DC breakers may be live even though the breakers are off.
•Be sure to test all terminals with a voltmeter before touching or using any tools.
•Always use caution when using metal tools to prevent contact with live parts or terminals.
•All installations must be in compliance with all local and national electrical codes and standards.
3