45
A
B
Hold new filter bag as shown. Align opening in filter bag with dirt tube (B). Push bag collar (A) firmly onto tube
(B).
Tuck in filter bag; zip outer bag.
The belt
The belt on your cleaner causes the agitator to rotate and is important for the effective operation of the cleaner. The belt is located under the bottom plate of the cleaner and should be checked from time to time to be sure it is in good condition.
When to replace
To check belt, remove bottom plate and hood as shown in “How to replace belt.” Replace belt if it is stretched, cut or broken.
What to buy
To assure effective operation, use only genuine Pacific Floor belts with your cleaner. When purchasing a new belt, ask for part No. 38528040.
46 |
|
| C |
A | A |
| |
B | B |
How to replace
Disconnect cleaner from electrical outlet.
Place handle in operating position and turn cleaner over so bottom side is up.
To remove bottom plate remove screws (A), insert end of flat screw- driver into wide area of
Lift extension (C) of bottom plate, rotate plate and remove from clean- er body.
47
48
F
E D
49
Remove agitator and broken agitator belt.
(If belt is not broken but is stretched or cut, proceed with steps for Figs. 50 to 53 and pull belt off motor pul- ley. Then continue with Fig. 48).
Slip agitator through new belt (with lettering toward outside of clean- er) and position belt in belt guide
(D). Push end of belt into opening in cleaner body.
Reposition agitator making sure to align flat sides of projection (E) on belt end of agitator with flat sides of slot (F) in cleaner body.
Place the three tabs on bottom plate into slots in front of cleaner body. Snap bottom plate into place over agitator.
10