Setup (Initial Settings)

5 Set the LOCAL/MENU/REMOTE switch to the LOCAL or REMOTE position.

The unit is set to the menu protect mode.

When the LOCAL/MENU/REMOTE switch is set to the MENU position, the menu setting mode is not established, and “MENU PROTECTED” appears on the video monitor screen.

<Note>

If the LOCAL/MENU/REMOTE switch is set to the MENU position while holding down the COUNTER button on the front panel, the menu setting mode will be established and the regular menu settings can be performed even in the menu protect mode.

Perform steps 2 through 7 of “Setting method using on-screen menus.” (See page 23)

How to release the menu protection

1 Set the LOCAL/MENU/REMOTE switch to the MENU position while holding down the COUNTER button on the front panel.

The unit is set to the menu setting mode, and the menu screen appears on the video monitor.

2 Perform steps 2 and 3 of “How to protect the menus.” and a screen for checking whether to protect the menus appears on the video monitor.

MENU PROTECT OK?

NO

YES

3 Press the MENU-UP button or MENU-DOWN button to move the cursor to the NO position, and press the SET button.

The menu protection is now released.

How to display the DIAG menu

This unit has a function for displaying hour meters, software version and the deck’s serial number on the video monitor.

1 Set the LOCAL/MENU/REMOTE switch to the MENU position while holding down the EJECT button.

The unit is set to the diagnosis display mode, and “HOURS METER” appears on the video monitor.

DIAG–MENU HOURS METER

Ser

H00

OPERATION

00000H

H01

DRUM RUN

00000H

H02

TAPE RUN

00000H

H03

THREADING

00000T

H11

DRUM RUN r

00000H

H12

TAPE RUN r

00000H

H13

THREADING r

00000T

Any item with “r” can be reset when servicing is performed.

2 While the hour meters are displayed, press the MENU-UP button or MENU-DOWN button while holding down the PAGE button.

The deck’s serial number and software version are displayed on the video monitor.

DIAG–MENU

VERSION

<NTSC>

 

 

 

FRONT

1.

-

 

IF

1.

-

- .

AV-SYSCON

1.

-

- .

DV

1.

-

- .

CYLINDER

1.

-

- .

REEL

1.

-

- .

 

 

 

 

When the MENU-UP button or MENU-DOWN button is pressed again while holding down the PAGE button, operation returns to the hour meter display.

3 Set the LOCAL/MENU/REMOTE switch to the LOCAL or REMOTE position.

Operation now returns to the normal mode.

26