Connection of the DC OUT connector and External
REC start/stop switch
It is possible to draw 1.5 A current from the DC OUT connector of the unit.
Recording start/stop can be controlled by connecting an external switch to this connector.
Since a tally lamp can be used by connecting an LED to this connector, it is useful for shooting video when fixing the camera on a crane.
Note
Make sure the total of current output from DC OUT, REMOTE, VF, and LENS connector do not exceed 2.5 A.
Preparation
DC OUT connector
Connector at the cable side
41
3 2
LED
Resistance
Max. 50 mA | Recording start/stop |
1:GND
2:TALLY OUT
Open collector output on the unit side.
TALLY ON: | Low impedance |
TALLY OFF: | High impedance |
3:Recording start/stop switch
This is connected in parallel to the REC START button on the unit or the VTR button on the lens.
4:+12 V
Preparation: Connection of the DC OUT connector and External REC start/stop switch 125