Parts and Their Functions

U

V

W

X

MON SEL

 

 

U MON SEL selector switch

 

PREVIEW

This switch is used to select the signals

 

B SUP

 

 

 

 

PED

 

G

SEQ

IRIS

(PUSH)

which are output from PIX OUT or WFM

ENC

 

R

 

 

 

OUT on the base station.

 

 

 

 

IRIS RANGE

 

 

V IRIS RANGE switch

FULL

 

 

 

 

 

 

This switch’s setting takes effect when the

SENSITIVITY

 

 

IRIS switch M has been set to MANUAL.

 

 

 

 

 

 

 

Y

When the IRIS RANGE switch is not at

 

 

 

 

the FULL position, the iris can be coarsely

 

RANGE

 

Z

adjusted by the RANGE control X and

 

 

 

 

finely adjusted by the iris control joystick

 

 

 

 

Y. In addition, the joystick’s operation

 

 

 

 

range can be varied using the

 

 

 

 

SENSITIVITY control W. When the IRIS

Remote Control Operation Panel AJ-

RANGE switch is set to FULL, the

 

 

 

 

SENSITIVITY control W and the RANGE

control X do not operate, and the iris is controlled using the iris control joystick Y.

WSENSITIVITY control

This is used to control the operation range of the iris control joystick Y when the IRIS RANGE switch V is at OFF.

XRANGE control

This is operational when the IRIS RANGE V switch is not set to FULL. It is used to coarsely adjust the iris.

YIris control joystick

When the IRIS switch M is at AUTO, the position set by the joystick is incremented or decremented to the AUTO IRIS LEVEL setting on the SETUP menu.

When the IRIS switch M is at MANUAL, the joystick is used to adjust the iris.

<Note>

Set the MANUAL/AUTO selector switch on the lens to AUTO.

ZM.PED control

This is used to set the master pedestal level.

E-7